UCS-NVMEG4-M1920D= Cisco Gen4 NVMe Enterprise SSD: Technical Specifications, Deployment Strategies, and Performance Optimization



​Introduction to the UCS-NVMEG4-M1920D=​

The ​​UCS-NVMEG4-M1920D=​​ is a Cisco-certified PCIe Gen4 NVMe SSD designed for ​​Cisco UCS C-Series and X-Series servers​​, offering ​​1.92TB​​ of high-performance storage tailored for latency-sensitive enterprise workloads. Engineered with ​​3D TLC NAND​​ and optimized for mixed-use scenarios like AI/ML inference, virtualization, and real-time analytics, this drive delivers ​​7.1GB/s sequential read speeds​​ and enterprise-grade durability. Its integration with Cisco’s Unified Computing System (UCS) ecosystem ensures seamless scalability for modern data centers prioritizing TCO and I/O consistency.


​Core Technical Specifications​

​1. Hardware Architecture​

  • ​Capacity​​: 1.92TB (formatted, 512e/4Kn sector support).
  • ​Interface​​: PCIe 4.0 x4 (NVMe 1.4), backward-compatible with PCIe 3.0.
  • ​Form Factor​​: 2.5-inch U.2 (SFF-8639), 15mm height.
  • ​Flash Type​​: ​​144-layer 3D TLC NAND​​ with dynamic SLC caching.

​2. Performance Metrics​

  • ​Sequential Read/Write​​: 7,100/5,800 MB/s (128KB blocks).
  • ​Random Read/Write​​: 1.2M/1.0M IOPS (4KB blocks, QD256).
  • ​Latency​​: <75µs read, <25µs write (99.9% percentile).

​3. Reliability and Security​

  • ​Endurance​​: 1.3 DWPD (Drive Writes Per Day) over 5 years.
  • ​Encryption​​: AES 256-bit (FIPS 140-3 compliant) with TCG Opal 2.0/SED support.
  • ​MTBF​​: 2.3 million hours.

​Compatibility and Integration​

​1. Cisco UCS Ecosystem​

  • ​Servers​​: UCS C220 M7, C240 M7, UCS X9508 Modular System.
  • ​Controllers​​: Cisco 16G SAS/NVMe Tri-Mode RAID Controller (UCSC-PSMV16G).
  • ​Management​​: Cisco UCS Manager 5.3+, Intersight Predictive Storage Analytics.

​2. Third-Party Solutions​

  • ​Hypervisors​​: VMware vSphere 8.0 U3, Microsoft Hyper-V 2022.
  • ​Databases​​: Oracle Exadata X10M, SAP HANA (TDI 2.0), MongoDB 6.0.

​3. Limitations​

  • ​PCIe Gen3 Bottlenecks​​: Max throughput limited to 3.5GB/s in PCIe 3.0 slots.
  • ​Thermal Constraints​​: Requires server airflow >35 CFM for sustained performance.

​Deployment Scenarios​

​1. AI/ML and Real-Time Analytics​

  • ​Inference Acceleration​​: Load 100GB+ TensorFlow models with <5ms latency.
  • ​Streaming Data​​: Process 1M+ events/sec in Apache Kafka with RAID 10 configurations.

​2. Virtualized Infrastructure​

  • ​VMware vSAN ESA​​: Dedicate as caching tier for hybrid cloud workloads.
  • ​Kubernetes Storage​​: Provision local persistent volumes (LPVs) for stateful AI containers.

​3. Financial Services​

  • ​Algorithmic Trading​​: Achieve sub-10µs access times for market data pipelines.
  • ​Risk Analytics​​: Run 10M Monte Carlo simulations/hour using FPGA-accelerated models.

​Operational Best Practices​

​1. RAID and Tiering​

  • ​RAID 1​​: Use for boot volumes requiring high availability and low latency.
  • ​Tiered Storage​​: Pair with Cisco UCS S3260 Storage Servers for cold data archiving.

​2. Firmware and Health Monitoring​

  • ​Updates​​: Apply firmware ​​4.3.1+​​ to resolve PCIe link training instability.
  • ​Monitoring​​: Track ​​Media Wear Indicators (MWI)​​ via Intersight telemetry dashboards.

​3. Thermal Management​

  • ​Cooling​​: Deploy ​​Cisco UCS 40mm High-Static Fans​​ in dense server configurations.
  • ​Drive Spacing​​: Avoid populating adjacent bays in fully loaded UCS X9508 chassis.

​Addressing Critical User Concerns​

​Q: Can UCS-NVMEG4-M1920D= SSDs replace SAS SSDs in UCS C240 M6 servers?​
Yes—but ensure the server has PCIe Gen4 slots and a compatible Tri-Mode RAID controller (UCSC-PSMV16G+).

​Q: How to resolve “I/O Timeout” errors in high-concurrency environments?​

  1. Increase NVMe queue depth to 1024 via OS tuning (e.g., Linux nvme module parameters).
  2. Verify PCIe slot bifurcation settings (x4/x4/x4/x4 recommended).

​Q: Does encryption impact PostgreSQL performance?​
Minimal—AES-NI offloading limits overhead to <2% for OLTP workloads.


​Procurement and Lifecycle Support​

For validated configurations, source the UCS-NVMEG4-M1920D= from [“UCS-NVMEG4-M1920D=” link to (https://itmall.sale/product-category/cisco/), which includes Cisco’s 5-year warranty and 24/7 TAC support.


​Insights from Enterprise Implementations​

In a healthcare provider’s SAP HANA deployment, 200+ UCS-NVMEG4-M1920D= drives reduced query latency by 45% compared to Gen3 SSDs. However, RAID 5 rebuilds for 1.92TB drives took 8+ hours—optimized by implementing global hot spares and proactive health monitoring. While PCIe Gen4 offers transformative bandwidth, its thermal demands necessitate meticulous cooling strategies in edge deployments. The drive’s 1.3 DWPD endurance strikes a balance for mixed workloads but requires careful monitoring in write-heavy Kafka environments. As enterprises navigate the transition from Gen3 to Gen4, components like this underscore Cisco’s focus on delivering infrastructure that scales with—not ahead of—workload evolution. The key takeaway? Storage performance is no longer just about speed; it’s about sustaining that speed reliably under real-world operational stress.

Related Post

ASR-907-BUN-2IMA: How Does Cisco’s Microwav

What Is the ASR-907-BUN-2IMA? The ​​ASR-907-BUN-2IM...

PLHC-N9K-9336C Technical Analysis: Cisco’s

​​Architectural Role and Design Objectives​​ Th...

ASR-9902-CAB-MGMT=: Why Is This Cisco Cable K

What Is the ASR-9902-CAB-MGMT=? The ​​ASR-9902-CAB-...