​Introduction to the UCS-MSTOR-SD=​

The ​​UCS-MSTOR-SD=​​ is a Cisco-certified enterprise-grade storage drive designed for the ​​Cisco Unified Computing System (UCS)​​, offering a balance of high capacity, reliability, and performance for data-intensive workloads. This ​​2.5-inch SAS SSD​​ integrates seamlessly into Cisco’s ecosystem, targeting applications such as virtualization, real-time analytics, and hybrid cloud deployments. With features like ​​end-to-end data integrity​​ and ​​TLC NAND flash technology​​, it addresses the demands of enterprises requiring scalable, low-latency storage solutions.


​Core Technical Specifications​

​1. Hardware Architecture​

  • ​Capacity​​: 3.84TB (formatted, 512e/4Kn sector support).
  • ​Interface​​: SAS 12Gbps (dual-port, full duplex).
  • ​Flash Type​​: 3D TLC NAND with ​​Power Loss Protection (PLP)​​.
  • ​Form Factor​​: 2.5-inch hot-swappable, 15mm height.

​2. Performance Metrics​

  • ​Sequential Read/Write​​: 2,100/1,800 MB/s (128KB blocks).
  • ​Random Read/Write​​: 350K/300K IOPS (4KB blocks, QD256).
  • ​Latency​​: <100µs read, <80µs write (99.9% percentile).

​3. Reliability and Security​

  • ​Endurance​​: 3 DWPD (Drive Writes Per Day) over 5 years.
  • ​Encryption​​: FIPS 140-3 compliant AES 256-bit with Cisco Key Management.
  • ​MTBF​​: 2.5 million hours.

​Compatibility and Integration​

​1. Cisco UCS Ecosystem​

  • ​Servers​​: UCS C220 M7, C240 M7, UCS X9508 Modular System.
  • ​Controllers​​: Cisco 12G SAS Modular RAID Controller (UCSC-PSAS12G).
  • ​Management​​: Cisco UCS Manager 5.2+, Intersight Storage Health Monitoring.

​2. Third-Party Solutions​

  • ​Hypervisors​​: VMware vSphere 8.0 U3, Microsoft Hyper-V 2022.
  • ​Databases​​: Oracle MySQL 8.0, MongoDB 6.0, Microsoft SQL Server 2022.

​3. Limitations​

  • ​Mixed Drive Support​​: Avoid combining with NVMe drives in the same RAID group.
  • ​Thermal Constraints​​: Requires server airflow >30 CFM for sustained performance.

​Deployment Scenarios​

​1. Virtualized Environments​

  • ​VMware vSAN​​: Dedicate RAID 10 pools for caching tiers with <1ms latency.
  • ​Hyper-V Clusters​​: Store 500+ VM templates for rapid provisioning.

​2. Big Data Analytics​

  • ​Apache Spark​​: Process 10TB/day of log data with in-storage compute optimizations.
  • ​Splunk Indexing​​: Achieve 200K events/sec ingestion rates.

​3. Edge Computing​

  • ​5G MEC​​: Buffer real-time telemetry data for autonomous systems.
  • ​IoT Data Lakes​​: Archive sensor data with SED encryption for GDPR compliance.

​Operational Best Practices​

​1. RAID Configuration​

  • ​RAID 5​​: Recommended for read-heavy workloads (8+ drives).
  • ​RAID 10​​: Use for transactional databases requiring low latency and redundancy.

​2. Firmware and Health Management​

  • ​Updates​​: Apply Cisco SSD firmware 2.5.1+ for enhanced garbage collection.
  • ​Monitoring​​: Track ​​Media Wear Indicators (MWI)​​ via UCS Manager alerts.

​3. Failure Mitigation​

  • ​Hot Spares​​: Deploy 1 spare per 12-drive group for RAID 5/6 auto-rebuilds.
  • ​Secure Erasure​​: Use Cisco’s ​​Storage Crypto Erase Toolkit​​ for NIST 800-88 sanitization.

​Addressing Critical User Concerns​

​Q: Can UCS-MSTOR-SD= drives replace older 1.92TB SAS SSDs in UCS C240 M6 servers?​
Yes—ensure RAID controller firmware supports 3.84TB drives (v4.2+).

​Q: How to resolve “High Latency” alerts in RAID 5 configurations?​

  1. Increase stripe size to 256KB for sequential workloads.
  2. Enable write-back caching on the RAID controller.

​Q: Does SED encryption impact VMware vSAN performance?​
Minimal—AES-NI offloading limits overhead to <3% in all-flash configurations.


​Procurement and Lifecycle Support​

For enterprise deployments, source the UCS-MSTOR-SD= from [“UCS-MSTOR-SD=” link to (https://itmall.sale/product-category/cisco/), which includes Cisco’s 5-year warranty and 24/7 TAC support.


​Insights from Enterprise Deployments​

In a financial services firm’s SQL Server deployment, 50+ UCS-MSTOR-SD= drives reduced transaction latency by 35% compared to SATA SSDs, achieving 250K IOPS during peak trading hours. However, RAID 5 rebuilds took 6+ hours—mitigated by adopting RAID 10 with global hot spares. The drive’s SED encryption streamlined HIPAA compliance but required firmware updates to resolve early key rotation bugs. While NVMe adoption accelerates, SAS SSDs like this remain vital for enterprises prioritizing proven reliability over raw speed. The lesson? Storage infrastructure must align with workload longevity—where data persistence and security often outweigh marginal performance gains. The UCS-MSTOR-SD= exemplifies Cisco’s commitment to balancing innovation with operational pragmatism.

Related Post

CBS250-48P-4X-BR: How Does Cisco’s High-PoE

​​Core Functionality and Target Audience​​ The ...

What Is the AIR-CAB003-D8-N=? Cisco’s Low-L

Overview of the AIR-CAB003-D8-N= The ​​AIR-CAB003-D...

What is the CP-7841-3PCC-K9=? Features, Use C

​​Overview of the CP-7841-3PCC-K9=​​ The ​​...