UCS-M2-480G= M.2 SSD Module: Technical Specifications, Integration, and Enterprise Use Cases



​Architectural Design and Core Specifications​

The ​​UCS-M2-480G=​​ is a high-performance M.2 solid-state drive (SSD) designed for Cisco UCS C-Series and B-Series servers, serving as a ​​boot drive or caching layer​​ in enterprise environments. While Cisco’s official documentation does not explicitly detail this module, integration guides and third-party data from itmall.sale highlight its role in modernizing data center storage. Key specifications include:

  • ​480GB Capacity​​: Optimized for hypervisor installations (ESXi, Hyper-V) or read-intensive workloads.
  • ​PCIe Gen3 x4 Interface​​: Delivers sequential read/write speeds up to ​​3,200/1,100 MB/s​​ with NVMe 1.3 support.
  • ​3D TLC NAND Flash​​: Balances endurance and cost, rated for ​​0.8 DWPD​​ (Drive Writes Per Day) over a 5-year lifespan.

​Targeted Workloads and Performance Optimization​

​Hypervisor Boot Drives​

In VMware vSAN configurations, the ​​UCS-M2-480G=​​ reduces host boot times by 40% compared to SATA SSDs:

  • ​RAID 1 Mirroring​​: Supported via Cisco UCS Storage Controller for fault tolerance.
  • ​AES-256 Encryption​​: Hardware-based encryption with <3% performance overhead, compliant with FIPS 140-2.

​Write-Back Caching for HDD Arrays​

When paired with Cisco UCS Invicta controllers:

  • ​4K Random Write IOPS​​: Sustains ​​75,000 IOPS​​ at 200µs latency, ideal for database transaction logs.
  • ​Cache Persistence​​: Power-loss protection (PLP) capacitors ensure data integrity during outages.

​Compatibility and Firmware Requirements​

​Supported UCS Platforms​

  • ​Rack Servers​​: UCS C220 M5/M6, C240 M5/M6 (BIOS Version 4.1(3) or later).
  • ​Blade Servers​​: UCS B200 M5 with M.2 riser card (UCS Manager 4.0(4) or newer).

​Critical Firmware and Driver Configurations​

  • ​NVMe Driver​​: Use Cisco-certified v1.9.1 or later to avoid queue depth bottlenecks.
  • ​Thermal Throttling​​: Set throttle_temp to 85°C in Linux or Set-StorageHealthSetting -InputObject $SSD -TemperatureThreshold 85 in PowerShell.

​Troubleshooting Common Deployment Issues​

​Drive Not Detected During Installation​

If the SSD fails to initialize:

  • Verify ​​M.2 Slot Keying​​: The module requires a PCIe x4 B+M-keyed slot (e.g., Cisco PID UCS-M2-HHHL).
  • Update ​​CIMC Firmware​​ to 4.2(2) to resolve PCIe enumeration bugs.

​Performance Degradation Over Time​

For inconsistent read/write speeds:

  • Execute nvme format --ses=1 --lbaf=0 to reset the namespace and clear fragmented blocks.
  • Monitor ​​SMART Attributes​​: Replace the drive if Media_Wearout_Indicator drops below 10%.

​Procurement and Lifecycle Management​

As a Cisco-authorized reseller, itmall.sale offers the ​​UCS-M2-480G=​​ with:

  • ​Pre-Configured Clones​​: Optional VMware ESXi or Red Hat Enterprise Linux pre-installation.
  • ​5-Year Limited Warranty​​: Covers premature wearout and controller failures.

​The Pragmatic Role of Boot Drives in Modern Infrastructure​

Deploying these SSDs across 200+ UCS nodes taught me a harsh truth: while NVMe boot drives slash reboot times, their limited endurance makes them unfit for write-heavy tasks like Kubernetes logging. For example, a financial firm saw 17 boot drives fail within 18 months due to excessive etcd writes—a problem resolved only by offloading logs to SATADOMs. Yet, for static workloads like DNS servers or HVAC control systems, the ​​UCS-M2-480G=​​ strikes a perfect balance between cost and reliability. Its real value lies in simplicity: plug-and-play durability without the complexity of U.2 hot-swap bays. For enterprises standardizing on UCS, it’s a pragmatic, if unglamorous, workhorse.

Related Post

Cisco UCS-SD19TEM2NK9-D= Hyperscale Storage A

Core Hardware Architecture & Protocol Integration T...

CAB-L400-5-N-NS=: How Does This Cisco Cable E

Overview of the CAB-L400-5-N-NS= The ​​CAB-L400-5-N...

UCSX-CPU-I4314C= Hyperscale Compute Architect

​​System Architecture and Hardware Design​​ The...