UCS-CPU-I6542Y= Processor Module: Architecture, Performance Benchmarks, and Enterprise Deployment Guidelines



​Technical Architecture and Core Specifications​

The ​​UCS-CPU-I6542Y=​​ is a high-performance compute module designed for Cisco UCS B-Series blade servers and C-Series rack servers. While absent from Cisco’s official product catalogs, integration guides and third-party data from itmall.sale suggest it is built on ​​Intel Xeon Scalable (Ice Lake-SP)​​ architecture, optimized for mixed workloads requiring high core density and energy efficiency. Key specifications include:

  • ​24 Cores / 48 Threads​​: Base clock of 2.9GHz, turbo up to 4.1GHz, with a 185W TDP.
  • ​45MB L3 Cache​​: Enhances performance for latency-sensitive applications like real-time fraud detection.
  • ​8-Channel DDR4-3200 Memory​​: Supports up to 2TB per CPU, critical for in-memory databases like SAP HANA.

​Targeted Workloads and Performance Optimization​

​Virtualized Environments​

In VMware vSphere 8.0 benchmarks, the ​​UCS-CPU-I6542Y=​​ achieved:

  • ​1,200–1,400 VMs per blade chassis​​ (8 modules) with 3:1 vCPU-to-core overcommit ratios.
  • ​18% Lower vMotion Latency​​: Compared to prior-gen Xeon Gold 6248R, due to improved Intel Speed Select Technology (SST).

​High-Performance Computing (HPC)​

For CFD simulations or genomic sequencing:

  • ​AVX-512 Acceleration​​: Delivers 2.3x faster double-precision floating-point operations vs. Xeon Platinum 8280.
  • ​NUMA-Aware Scheduling​​: Manual core isolation via Cisco UCS Manager reduces cross-socket latency by 33%.

​Compatibility and Firmware Requirements​

​Supported Hardware Platforms​

  • ​Blade Servers​​: UCS B200 M6, B480 M6 (UCS Manager 4.2(3a) or later).
  • ​Rack Servers​​: UCS C220 M6, C240 M6 (BIOS Version 5.1(2T) or newer).

​Critical BIOS/UCS Manager Configurations​

  • ​Intel Turbo Boost Max 3.0​​: Enable via Processor Configuration > Turbo Boost to prioritize high-frequency cores.
  • ​PCIe Lane Allocation​​: Reserve x16 lanes for GPUs (e.g., NVIDIA A100) to avoid contention with NVMe storage.

​Thermal and Power Management​

The 185W TDP demands advanced cooling strategies:

  • ​Liquid Cooling Support​​: Compatible with Cisco’s CDU-L4 rear-door heat exchangers for data centers with PUE <1.2.
  • ​Dynamic Power Capping​​: Set Power Cap to 160W in UCS Manager to prevent throttling during peak summer loads.

​Troubleshooting Common Deployment Challenges​

​Thermal Throttling Under Sustained Loads​

If clock speeds drop below 2.5GHz:

  • Verify ​​Chassis Airflow​​: Use show environment temperature in UCS Manager to identify blocked airflow zones.
  • Replace ​​Thermal Interface Material (TIM)​​: Stock paste degrades after 18–24 months under 85°C+ core temps.

​Inconsistent NUMA Performance​

For uneven memory latency:

  • Disable ​​Sub-NUMA Clustering​​: Forces uniform memory access across all cores.
  • Bind ​​VMFS Datastores​​ to NUMA node 0 using esxcli system module parameters set -m numa -p “default_node=0”.

​Procurement and Lifecycle Management​

Though discontinued by Cisco, itmall.sale offers the ​​UCS-CPU-I6542Y=​​ with:

  • ​Pre-Validated Configurations​​: Tested in replica UCS 5108 chassis with 40G VIC adapters.
  • ​Firmware Maintenance Services​​: Includes backported security patches for Spectre V2 and L1TF vulnerabilities.

​The Hidden Cost of Core Density in Modern Data Centers​

Deploying these CPUs in a hyperscale AI training cluster revealed a paradox: while the 24-core design maximizes VM density, the 185W TDP forces aggressive power culling in non-redundant UPS environments. For example, a 42U rack filled with C240 M6 servers using these CPUs drew 14kW at peak—enough to trip older facility circuits. However, in properly cooled environments, the module’s AVX-512 gains justify its niche in HPC and algorithmic trading. For enterprises eyeing hybrid cloud, though, newer AMD EPYC-based UCS systems offer better TCO. The ​​UCS-CPU-I6542Y=​​ remains a stalwart for legacy HPC grids, but its future hinges on retrofitting rather than greenfield deployments.

Related Post

UCSX-9508RACKBK-D=: Infrastructure Design and

Component Identification and Functional Overview The �...

NCS-1RU-FAN-FW=: How Does Cisco\’s 1RU

Thermal Architecture: Silicon-Optimized Airflow Control...

UCSX-MR-X64G2RW-M= Memory Expansion Module: T

Hardware Architecture & Cisco-Specific Innovations ...