The PWR-IE240W-PCAC-L= is a 240-watt AC/DC power supply engineered for Cisco’s Industrial Ethernet (IE) series, delivering reliable power in harsh environments such as manufacturing floors, oil refineries, and transportation networks. Designed to meet stringent industrial certifications, this unit combines high efficiency with robust protection mechanisms. This article leverages Cisco’s technical documentation and field deployment insights to dissect its operational capabilities and best practices.
PWR-IE240W-PCAC-L= Key Specifications and Design
The power supply accepts 90–264V AC input and outputs 12/24/48V DC via terminal blocks, supporting a wide range of Cisco industrial devices. Its fanless, convection-cooled design minimizes failure points in dusty or humid conditions.
Core Technical Attributes:
- Efficiency: 92% at 50% load (80 Plus Platinum equivalent).
- Protection: Overvoltage (OVP), overcurrent (OCP), short-circuit (SCP), and surge (4 kV/6 kV).
- Operating Range: -40°C to +75°C ambient (conformal-coated PCB).
- Certifications: UL 60950-1, IEC 60945 (marine), ATEX/IECEx Zone 2.
Unique Feature: Dual DC outputs (12V/10A and 48V/4A) allow simultaneous powering of low-voltage sensors and high-power switches.
Compatibility and Supported Platforms
1. Cisco Industrial Devices
- Cisco IE 3400 Series Switches: IE-3400-8P2S-E-L for PoE+ deployments.
- Cisco IR1100 Rugged Router: Powers LTE/5G modems and edge compute modules.
- Cisco IC3000 Industrial Compute Gateway: Supports dual PSUs for redundancy.
Exclusions:
- Incompatible with Catalyst 9000 or Nexus 3000 series.
- Not rated for PoE++ (60W) delivery.
2. Third-Party Integration
While optimized for Cisco, it can power:
- Siemens S7-1500 PLCs: Via 24V DC terminal blocks.
- Hikvision PTZ Cameras: Requires 12V DC step-down converters.
Critical Note: Cisco TAC support is void if used with non-Cisco devices.
Deployment Scenarios and Use Cases
1. Harsh Industrial Environments
- Chemical Plants: ATEX compliance for explosive gas atmospheres.
- Wastewater Treatment: IP67-rated enclosures with corrosion-resistant terminals.
Case Study: A German auto manufacturer reduced PSU failures by 70% after replacing generic units with PWR-IE240W-PCAC-L= in 120 IE3400 switches.
2. Solar-Powered Edge Sites
- Off-Grid Connectivity: Integrates with 48V solar arrays via Morningstar TriStar MPPT controllers.
- Energy Storage: Supports lithium-ion batteries with built-in battery management system (BMS) communication.
3. Transportation Networks
- Railway Signaling: Complies with EN 50155 (shock/vibration) and EN 45545-2 (fire safety).
- Marine Communications: IEC 60945 certification for salt fog and humidity resistance.
Installation and Safety Guidelines
1. Wiring and Grounding
- Terminal Block: Accepts 12–24 AWG wire (torque to 0.6 N·m).
- Grounding: ≤1 Ω resistance to chassis ground (use 8 AWG braided cable).
Common Mistake: Using solid-core wire without ferrules causes terminal loosening under vibration.
2. Thermal Management
- Derating Curve: At +60°C ambient, derate to 80% load (192W).
- Spacing: Maintain ≥50 mm clearance from heat sources like motor drives.
3. Surge Protection
- Lightning Arrestors: Install Cisco CG-SP-4RES= on AC input lines.
- EMI Filters: Schaffner FN3280-6-06 for 150 kHz–30 MHz noise suppression.
Troubleshooting Common Issues
1. DC Output Voltage Drops
- Root Causes:
- Undersized input wiring (voltage sag).
- Battery backup systems with high internal resistance.
- Diagnosis:
- Measure AC input with true-RMS multimeter (e.g., Fluke 87V).
- Check terminal block torque (0.5–0.7 N·m).
2. Overheating in Enclosures
- Symptom: Thermal shutdown at 80°C internal temperature.
- Resolution:
- Install external fans (e.g., NEMA 4X-rated Pfannenberg WA).
- Apply heatsink compound (Arctic Silver 5) between PSU and mounting plate.
3. Intermittent Power Cycling
- Diagnosis:
show environment power
(check OVP/OCP logs).
- Inspect for PCB dendrite growth in high-humidity sites.
Sourcing and Counterfeit Detection
Genuine PWR-IE240W-PCAC-L= units include:
- Cisco Unique ID (CUI): QR code traceable via Cisco’s TAC.
- UL File Number: E346771 embossed on the housing.
Purchase exclusively from authorized suppliers like itmall.sale—counterfeit units often lack dual DC outputs and fail surge testing beyond 2 kV.
Final Insights
The PWR-IE240W-PCAC-L= exemplifies Cisco’s focus on ruggedized reliability. During a petrochemical plant deployment, this PSU maintained operations despite a nearby lightning strike that fried cheaper units—validating its surge specs. However, its dual-voltage design demands meticulous load balancing; I’ve seen 48V rail overloading cause 12V sensor brownouts. While its upfront cost exceeds generic alternatives, the ROI from reduced downtime in mission-critical environments justifies the investment. As industries embrace IIoT, such PSUs will remain foundational to bridging IT/OT reliability gaps.