​Functional Role and Regional Compliance​

The ​​PWR-CAB-AC-SA=​​ is a ​​Saudi Arabia-specific AC power cable​​ designed for Cisco networking and server equipment, meeting ​​SASO (Saudi Standards, Metrology, and Quality Organization)​​ and ​​IEC 60884-1​​ requirements. Engineered for ​​220–240V AC, 60Hz​​ electrical grids, this cable ensures compatibility with Saudi Arabia’s infrastructure while addressing extreme environmental conditions like desert heat and sand exposure. Cisco mandates its use with ​​Catalyst 9000 switches​​, ​​UCS C-Series servers​​, and ​​ASR 9000 routers​​ to maintain warranty compliance and operational reliability in critical sectors like oil/gas and smart cities.


​Core Technical Specifications​

―――――――――――――――――――――――――――――――――――――――――――

  • ​Electrical Ratings​​:

    • ​Voltage​​: 250V AC, 13A (3.25kW max)
    • ​Plug Type​​: SASO Type G (BS 1363-5A, 3-pin)
    • ​Cable Gauge​​: 13 AWG (2.5mm²) with 450/750V insulation
  • ​Environmental and Safety Features​​:

    • ​Temperature Range​​: -40°C to 75°C (thermoplastic elastomer jacket)
    • ​Fire Resistance​​: IEC 60332-1-2 Cat A flame-retardant
    • ​Certifications​​: SASO-IEC 60884-1, RoHS 3
  • ​Mechanical Durability​​:

    • ​Bend Radius​​: ≥35mm (2,000+ flex cycles)
    • ​Pull Strength​​: 45kgf (441N) tensile resistance

―――――――――――――――――――――――――――――――――――――――――――

  • ​Compatibility​​:
    Cisco Catalyst 9300/9400, UCS C220 M6/C480 ML, and ASR 9904/9912.

​Deployment Scenarios and Regulatory Validation​

―――――――――――――――――――――――――――――――――――――――――――
​Case 1: Aramco’s IoT-Enabled Oil Refineries​

  • Deployed in ​​Ras Tanura Refinery​​ for Catalyst 9300 switches:
    • Withstood 55°C ambient temps and sandstorms via IP54-rated connectors.
    • Met ​​SASO 2203:2018​​ requirements for hazardous location wiring.

​Case 2: NEOM Smart City Backbone​

  • Used in ​​NEOM’s OXAGON industrial zone​​ for ASR 9912 routers:
    • Survived 85% humidity in coastal areas with anti-corrosion nickel-plated pins.
    • Enabled ​​SLA 99.999% uptime​​ under Saudi Electricity Company grid fluctuations.

​Integration Challenges and Mitigation Strategies​

―――――――――――――――――――――――――――――――――――――――――――

  1. ​Plug Type Mismatch in Legacy Facilities​​:

    • ​Symptom​​: Incompatibility with Type F (Schuko) outlets in Jeddah’s older data centers.
    • ​Resolution​​: Deployed ​​Cisco CAB-ADPT-SA-F​​ SASO-certified adapters.
  2. ​Voltage Fluctuations in Remote Sites​​:

    • ​Trigger​​: 180V sags caused UCS C480 ML servers to reboot in Empty Quarter deployments.
    • ​Fix​​: Installed ​​Cisco CAB-AVR-3K​​ automatic voltage regulators.
  3. ​Dust Ingress in Desert Environments​​:

    • ​Issue​​: Sand particles jammed plug contacts at Ma’aden mining sites.
    • ​Mitigation​​: Applied ​​Cisco CAB-SEAL-SA​​ silicone boot covers.

Source certified PWR-CAB-AC-SA= cables to avoid compliance penalties.


​Performance Benchmarks vs. Non-Certified Cables​

―――――――――――――――――――――――――――――――――――――――――――

  • ​Safety​​:
    Passed 5kV HiPot testing vs. 2kV for generic cables – critical for SASO’s HV grid standards.
  • ​Heat Resistance​​:
    No insulation softening at 75°C vs. deformation at 60°C in uncertified cables.
  • ​Dust Protection​​:
    IP54 rating vs. IP20 for non-SASO cables – reduced maintenance by 70% in desert sites.
  • ​TCO​​:
    SAR 350 vs. SAR 90 for generic – justified by 5-year warranty and 90% lower failure rates.

​Operational Best Practices​

―――――――――――――――――――――――――――――――――――――――――――

  1. ​Installation Protocol​​:

    • Torque plug screws to ​​0.8–1.0Nm​​ using ​​Cisco CAB-TQ-SA​​ tools.
    • Maintain ≥40mm clearance from high-voltage DC busbars to prevent arcing.
  2. ​Preventive Maintenance​​:

    • Test insulation resistance biannually (≥1GΩ @ 1,000V DC) with Megger MIT515.
    • Clean plug contacts quarterly using ​​Cisco CAB-CLR-SA​​ non-conductive spray.
  3. ​Regulatory Audits​​:

    • Verify SASO Conformity Tracking Number (CTN) and IECEE-CB certification.
    • Replace cables showing ≥2mm jacket cracks or discolored insulation.

​Strategic Insights for Saudi Infrastructure Teams​

While the PWR-CAB-AC-SA= addresses Saudi Arabia’s harsh operational realities, its ​​premium pricing​​ often tempts cost-driven projects to use non-compliant alternatives – a false economy given ​​2023 Saudi Energy Ministry fines of SAR 500k per violation​​ for non-certified components. The cable’s ​​fixed 13A rating​​ also limits scalability for 20A server clusters emerging in Riyadh’s AI hubs. However, for enterprises prioritizing ​​Vision 2030 compliance​​ and ​​equipment longevity​​, this cable’s SASO alignment and rugged design remain indispensable. As Saudi transitions to smart grids and renewable energy, the need for adaptive power infrastructure will grow – but today, the PWR-CAB-AC-SA= stands as the definitive solution for bridging legacy grids with future-ready networks.