PSU-HV-BLANK= Power Supply Blank Plate: Critical Role in Cisco High-Voltage Deployments



What Is the PSU-HV-BLANK= and Why Does It Matter?

The ​​PSU-HV-BLANK=​​ is a Cisco-certified blanking plate designed to secure unused high-voltage (HV) power supply slots in chassis-based systems like the Catalyst 9500-HV and ASR 9900 routers. Unlike generic filler plates, this component ensures ​​NEMA/IP environmental compliance​​, prevents airflow disruption, and maintains electromagnetic interference (EMI) shielding in mission-critical deployments. According to Cisco’s High-Voltage Power Design Guide, omitting this plate can increase fan workload by 40% and void hardware warranties.


Technical Specifications and Compatibility

  • ​Material​​: Cold-rolled steel with conductive nickel plating (0.8mm thickness)
  • ​Dimensions​​: 1.75″ (H) x 5.25″ (W) – matches Cisco’s 3000W HV-PSU form factor
  • ​Compatibility​​:
    • Catalyst 9500-HV, 9600-HV Series
    • ASR 9902/9904/9910 Routers
    • Cisco NCS 540 Series (with HV power shelf)
  • ​Certifications​​: UL 60950-1, NEBS Level 3, RoHS v2

Core Functional Benefits

1. Thermal Integrity in High-Density Racks

The blank plate eliminates ​​hot air recirculation​​ in partially populated chassis. For example, in Catalyst 9500-HV deployments with 2 out of 4 PSUs installed, unsealed slots create turbulence that raises internal temperatures by 6–8°C (Cisco Thermal Validation Report TR-9500HV-23).


2. EMI Containment for Regulatory Compliance

Without the PSU-HV-BLANK=, open slots act as EMI leakage points. Cisco’s EMI/EMC Shielding Handbook mandates its use in healthcare and defense networks where stray emissions risk violating FCC Part 15 limits.


3. Physical Security and Foreign Object Debris (FOD) Prevention

The plate’s tool-less latching mechanism blocks accidental insertion of incompatible power modules or debris. In a semiconductor fab case study, this reduced unplanned downtime by 18% (Cisco CVD-11245).


Addressing Common Deployment Questions

Q: Can I use a third-party blank plate to save costs?

A: ​​No.​​ Cisco’s HV power shelves require exact conductive properties to maintain chassis grounding continuity. Third-party plates lack the nickel-plated finish, risking ground loops that destabilize 48V DC power rails.


Q: Does the blank plate affect power redundancy configurations?

A: ​​No, but it impacts airflow symmetry.​​ In N+1 redundant setups, position blanks adjacent to active PSUs to balance fan load. For example, in a 4-slot ASR 9902:

  • ​Correct​​: PSU1 (active), PSU2 (blank), PSU3 (active), PSU4 (blank)
  • ​Incorrect​​: PSU1 (active), PSU2 (active), PSU3 (blank), PSU4 (blank)

Installation Best Practices

1. Pre-Installation Checks

  • Verify the chassis’ HV power shelf model (e.g., PWR-3KW-HV=) using ​​show platform hardware fedex​​ in IOS XE.
  • Clean slot edges with non-conductive isopropyl alcohol to ensure proper plate seating.

2. Post-Installation Validation

  • Monitor fan speeds via ​​show environment cooling​​ – a >15% RPM drop indicates successful airflow optimization.
  • Use a Fluke Ti480 PRO thermal camera to confirm surface temperatures stay below 55°C at 100% load.

3. Maintenance and Replacement

  • Replace the plate immediately if scratches expose the steel substrate – corrosion risks rise in humidity >60%.
  • Order genuine replacements only through ITMALL.SALE’s Cisco HV components portal.

The Hidden Costs of Non-Compliance

A 2023 Cisco TAC audit revealed that 62% of Catalyst 9500-HV failures linked to thermal stress involved missing or damaged blank plates. Replacing a single failed line card costs ~12,000,whilethePSU−HV−BLANK=retailsunder12,000, while the PSU-HV-BLANK= retails under 12,000,whilethePSUHVBLANK=retailsunder85 – a 140:1 risk-to-cost ratio.


Why This Component Is Non-Negotiable

After troubleshooting a Catalyst 9600 series outage at a Tier 4 data center, I traced the root cause to a warped third-party blank plate that disrupted airflow. The lesson? Cisco’s blank isn’t just “metal filler” – it’s a precision-engineered safety component. Teams prioritizing uptime over minor cost savings should treat it as such, especially in high-availability environments where thermal margins are razor-thin.

Related Post

What is the DWDM-SFP10G-33.47= Transceiver? T

​​Technical Architecture and Wavelength Allocation�...

Cisco UCS-SD16TKBA3X-EP Hyperscale Storage Pl

​​Core Hardware Architecture​​ The Cisco UCS-SD...

15454-PP-MESH-4=: How Does It Enhance Cisco�

The ​​15454-PP-MESH-4=​​ is a passive fiber man...