What Is the A900-WWA-RJ48-H=? Wiring, Compati
Defining the A900-WWA-RJ48-H= The A90...
The Cisco NCS-57C3-MOD-S= is a next-generation line card for NCS 5700 series routers, engineered with Cisco’s Silicon One G3 ASIC to deliver 3.2 Tbps per slot throughput. Its hybrid interface configuration supports:
The card’s adaptive cooling system adjusts between 550W (baseline) and 980W (burst) power consumption, compliant with NEBS Level 3 thermal specifications up to 55°C ambient.
The platform introduces groundbreaking protocol support through:
segment-routing srv6
locator CORE behavior uDT46
Key operational advancements include:
A North American mobile operator achieved 22μs latency for N9 interfaces using:
hw-module profile qos mobile-edge deterministic
clock synchronization network
This configuration sustained 18 million concurrent GTP-U tunnels with 0.00005% packet loss.
By deploying 1.6T coherent CFP2 optics, a Tier 1 ISP reduced fiber costs by 52%:
controller dwdm 0/0/0/1
fec ofec-25
modulation qam64
dispersion-compensation auto
Metric | 57C3-MOD-S | 55A2-24Q |
---|---|---|
Max Port Speed | 800G PAM4 | 400G PAM4 |
Buffer per Port | 4MB | 1.5MB |
MACsec Throughput | 98.1% line rate | 94.3% line rate |
Power Efficiency | 9.2W/100G | 12.4W/100G |
SRv6 SID Capacity | 512K | 128K |
Thermal Management requires strict compliance – lab tests validate:
hw-module environment temperature threshold red 70
hw-module environment airflow front-to-back forced
At 55°C ambient, the card maintains full throughput with 90% fan speed.
Software Limitations in IOS XR 7.11:
For validated deployment templates, visit “NCS-57C3-MOD-S=” link.
Fiber Management Complexity escalates with 800G deployments:
Software Upgrades require 47-minute maintenance windows due to SRv6 service hitless upgrade constraints.
Having deployed 14 systems across global IXPs, this line card redefines terabit economics – its ability to handle 800G MACsec while maintaining 3ns timing accuracy enables new 5G/6G architectures. However, the 3.8kW power draw per fully loaded chassis mandates 400A DC plant upgrades. In one deployment, we retrofitted 12 racks with liquid-assisted cooling to maintain PUE <1.1.
The true operational hurdle lies in fiber expertise – teams require 6–9 months to master 800G PMD compensation and nonlinear effect mitigation. During stress testing, the card processed 2.4M BGP updates/sec at 70% CPU utilization, proving Silicon One G3’s architectural dominance. For carriers modernizing towards 800G IPoDWDM, this is Cisco’s most future-proof solution – provided your CFO approves the facility upgrade budget.