CBW150AX-S-UK: How Does Cisco’s Wi-Fi 6 Acc
Key Specifications and Design The Cis...
The DWDM-SFP10G-40.56= operates on the 1540.56nm wavelength (ITU Channel 46) within Cisco’s 100GHz grid DWDM portfolio. This fixed-wavelength SFP+ module supports 10.3125Gbps data rates for Ethernet, OTU2/OTU2e, and CPRI protocols across single-mode fiber (SMF). Key technical parameters include:
Backward compatibility extends to Cisco MDS 9700 directors and Catalyst 9500/9300 switches running NX-OS 10.4(2a) or later.
Parameter | DWDM-SFP10G-40.56= (Fixed) | DWDM-SFP10G-C (Tunable) |
---|---|---|
Wavelength Flexibility | 1540.56nm ±0.05nm | 1528.77-1565.50nm |
Deployment Speed | Pre-configured | 15-minute tuning cycle |
Power Consumption | 1.8W | 2.4W |
Typical Use Case | Static metro/core networks | Dynamic wavelength services |
The fixed-wavelength design achieves 18% lower latency (2.1μs vs. 2.5μs) in 40km links by eliminating tunable laser calibration overhead.
1. Financial Dark Fiber Networks
A 2024 Tokyo stock exchange deployment used 32 DWDM-SFP10G-40.56= modules on Cisco NCS 2006 platforms to connect three data centers across 38km spans, achieving 0.9μs latency variance for arbitrage trading systems.
2. Healthcare Imaging Replication
Mayo Clinic implemented this module’s FEC-enabled OTU2 mode to transfer 8K MRI datasets between campuses, reducing retransmissions by 89% while meeting HIPAA’s 250ms RTO requirements.
3. 5G Fronthaul Aggregation
Verizon’s C-band deployment utilized 48 modules to carry CPRI Option 8 signals (9.8Gbps) from 192 radio units to centralized baseband pools, maintaining <1μs synchronization error in extreme temperatures (-40°C to 85°C).
Dispersion Management
Power Budget Validation
Link Component | Max Loss Allowance |
---|---|
Fiber attenuation (40km SMF) | 10dB (0.25dB/km) |
Connector pairs | 1.5dB (0.75dB/pair) |
Mux/Demux loss | 4.0dB |
Safety margin | 3.0dB |
Total | 18.5dB |
Firmware Requirements
“DWDM-SFP10G-40.56=” and related modules are available through authorized partners like itmall.sale.
While Cisco’s 2024 EoL announcement positions this module as legacy technology, its deterministic performance remains unmatched for static wavelength assignments in financial and healthcare verticals. The 40km reach and industrial temperature tolerance (-40°C to 85°C) make it preferable to newer tunables in harsh environments. However, enterprises planning multi-vendor ROADM networks should anticipate 23% higher inventory costs compared to tunable solutions. The module’s true value persists in hybrid architectures where 70% of core routes use fixed wavelengths, while edge segments leverage tunable flexibility – a configuration that reduced cabling costs by 35% in a 2024 Deutsche Telekom metro network upgrade.