Cisco UCS-NVM2-400GB= Enterprise NVMe SSD: Technical Specifications and Deployment Best Practices



Hardware Architecture and Core Design

The Cisco UCS-NVM2-400GB= is a ​​400GB NVMe 1.3 Enterprise SSD​​ designed for read-intensive workloads in UCS C-Series servers. Built on ​​64-layer 3D TLC NAND​​ with a PCIe Gen3 x4 interface, it delivers ​​3.2GB/s sequential read​​ and ​​1.1GB/s write speeds​​ at 75μs latency. Key innovations include:

  • ​Form Factor​​: M.2 2280 (Single-Sided, 22mm x 80mm)
  • ​Endurance​​: 1.3 DWPD (Drive Writes Per Day) over 5-year warranty
  • ​Security​​: ​​TCG Opal 2.0​​ self-encryption with AES-256-XTS
  • ​Power Loss Protection​​: 10ms holdup via ceramic capacitors
  • ​QoS​​: 250K IOPS (4K random read) with <15% latency deviation

Platform Compatibility and Configuration

Q: Which UCS platforms are validated for this drive?

A: Certified configurations include:

  • ​UCS C220 M5/M6​​ (UCS Manager 4.1(3a)+)
  • ​HyperFlex HX220c M5 nodes​​ (VMware vSAN 7.0U3+)
  • ​UCS S3260 storage servers​​ in RAID 1/10 configurations

​Installation protocol​​:

  1. Disable SATA controller mode in BIOS/UEFI
  2. Install in PCIe Gen3 x4 slot with thermal pad (1.0mm thickness)
  3. Enable ​​Namespace Sanitize​​ for cryptographic erase
  4. Validate firmware via ​​Cisco HUU 3.2.1b+​

Performance Benchmarks

Third-party testing under SNIA SSSI PTB v3.1 reveals:

Metric UCS-NVM2-400GB= SATA SSD (480GB)
​4K Random Read​ 250K IOPS 98K IOPS
​128K Sequential Read​ 3.2GB/s 540MB/s
​Latency Consistency​ ±12% ±25%
​Power Efficiency​ 35K IOPS/W 12K IOPS/W

​Enterprise workload validation​​:

  • Sustains ​​8,000 VDI sessions​​ with 4ms P99 boot latency
  • Processes ​​14K IOPS​​ in Oracle DB redo log operations

Enterprise Use Cases

Organizations implementing [“UCS-NVM2-400GB=” link to (https://itmall.sale/product-category/cisco/) achieve:

  1. ​Virtualized Infrastructure​
    Supports 160 VMs per host (4vCPU/8GB RAM each)

  2. ​Distributed Caching​
    Reduces MongoDB query latency from 8ms to 1.2ms

  3. ​Video Surveillance Storage​
    Handles 64x 4K camera streams (30fps H.265)


Advanced Reliability and Security

​Five-nines availability features​​:

  • ​End-to-End Data Path Protection​​: T10 PI (Protection Information)
  • ​Adaptive Thermal Monitoring​​: Auto-throttles at 75°C
  • ​Bad Block Management​​: Spares 7% NAND capacity

​Compliance certifications​​:

  • FIPS 140-2 Level 2 (Pending FIPS 140-3 upgrade Q4 2024)
  • HIPAA-compliant secure erase workflows
  • TAA compliance for government deployments

Thermal and Power Management

​Thermal thresholds​​:

Component Normal Range Throttle Threshold
Controller 40°C–70°C 80°C
NAND 30°C–65°C 75°C

​Power profiles​​:

  • ​Idle​​: 1.8W (PS3 sleep state)
  • ​Active​​: 5.2W (PCIe Gen3 x4 operation)
  • ​Burst​​: 6.5W (15-second peak writes)

Lifecycle Management

​Operational challenges​​:

  • PCIe link training failures in legacy M.2 slots
  • Write amplification spikes beyond 85% capacity
  • Firmware conflicts with non-Cisco NVMe drivers

​Proactive maintenance​​:

  • ​Monthly​​: Check wear level via ​​Cisco Intersight Storage Analytics​
  • ​Quarterly​​: Rotate drives in RAID arrays to balance wear
  • ​Biannually​​: Update firmware using ​​Cisco Host Upgrade Utility​

Comparative Analysis

Feature UCS-NVM2-400GB= UCS-NVM1-200GB=
​Capacity​ 400GB 200GB
​Interface​ PCIe Gen3 x4 PCIe Gen3 x2
​DWPD​ 1.3 0.8
​Encryption​ TCG Opal 2.0 TCG Enterprise

TCO Insights

Data from 32 deployments shows:

  • 42% lower $/IOPS compared to SATA SSDs
  • 18% reduction in power consumption per drive
  • 3:1 consolidation ratio for web server farms

Field Deployment Perspectives

In a global retail chain’s POS system, the ​​75μs read latency​​ enabled real-time inventory updates across 12,000 stores – until engineers discovered that enabling TCG Opal added 8μs overhead, requiring adjustments to transaction batch sizes. The ​​10ms PLP​​ proved critical during 14 power outages, preventing 2.1PB of transaction loss.

However, achieving consistent 3.2GB/s throughput required disabling ​​ASPM power states​​ – a configuration oversight that initially caused 18% performance variance. Healthcare adopters reported thermal throttling in poorly ventilated edge racks until adding 40mm airflow fans.

The ​​M.2 2280 form factor​​ allowed retrofitting legacy UCS C220 M4 chassis, though three financial institutions required custom brackets for vibration dampening in trading floor deployments. While marketed for read-intensive workloads, the drive unexpectedly excelled in Kafka message brokering – its ​​T10 PI protection​​ prevented 1.4M message corruptions in a 6-month period.

The UCS-NVM2-400GB= embodies Cisco’s balance of performance and practicality. Its value becomes apparent not in lab benchmarks, but in surviving real-world chaos – from monsoons flooding data centers to Black Friday traffic spikes. In enterprise storage, such resilience transforms “uptime” from a metric into a competitive advantage. Those who pair it with Cisco’s predictive analytics unlock its full potential, while others merely scratch the surface of its capabilities.

Related Post

C9K-PWR-1600WAC-R=: How Does It Power High-De

​​What Is the C9K-PWR-1600WAC-R=?​​ The ​​C...

UCSX-FI-64108-CH: Cisco’s Next-Generation F

​​Architectural Role of the UCSX-FI-64108-CH​​ ...

Cisco NXA-QDD-CU1M=: Technical Design, Deploy

​​Product Overview and Functional Role​​ The �...