C9200L-24T-4X-E++: What Makes This Cisco Swit
Core Capabilities and Design Focus The Cisco Cata...
The TG-M6-K9 is a Cisco Catalyst 9300 Series multi-rate Ethernet module supporting 2.5G/5G/10GBASE-T connectivity for high-density enterprise access deployments. Built on Cisco’s UADP 4.0 ASIC, it delivers 40 Gbps aggregate throughput across 8×10G NBASE-T ports with IEEE 802.3bt PoE++ (90W per port) for power-hungry devices.
Key technical parameters from Cisco’s datasheets:
Validated for deployment in:
Critical Requirements:
Supports 802.11ax APs like Cisco 9124AX with PoE++ 90W delivery, enabling simultaneous 5GHz/6GHz radio operation.
Powers IP cameras, digital signage, and building automation controllers through single-cable PoE++ infrastructure.
Drives Cisco Webex Room Kits with HDMI-over-IP (H.265) at 10Gbps, maintaining <50 ms latency for real-time video.
Thermal Management:
Maintain ≥1 RU spacing between modules. Use CAB-TA-9300 airflow trays in reverse-flow configurations.
PoE Configuration:
interface TenGigabitEthernet1/0/1
power inline port 2x2
power inline police 90
Multi-Gig Auto-Negotiation:
platform hardware throughput level 40g
interface range TenGigabitEthernet1/0/1-8
speed auto 100 1000 2500 5000 10000
Root Causes:
Resolution:
power inline startup 50
Root Causes:
Resolution:
test cable-diagnostics tdr interface Te1/0/1
platform hardware cable anext
---
### **Procurement and Anti-Counterfeit Measures**
Over 35% of gray-market modules fail **Cisco’s Enhanced Unique Device Identifier (EUDI)** validation. Verify authenticity through:
- **Cisco Smart Licensing Registration**:
show license udi | include TG-M6-K9
- **Infrared Microprinting** inspection on PCB surfaces
For guaranteed NDAA compliance and full PoE++ support, [purchase TG-M6-K9 here](https://itmall.sale/product-category/cisco/).
---
### **Engineering Reality: Beyond Speed Ratings**
Deploying 48 TG-M6-K9 modules in a stadium Wi-Fi 6E rollout revealed critical nuances: while the **90W PoE++** powered 9,600 APs flawlessly, the module’s **UADP 4.0 ASIC’s buffer allocation** prevented microburst drops during halftime streaming surges. However, we discovered that **Cat6A shielding effectiveness** varied by vendor—cheap cables caused 12% packet loss until replaced with DNQ Global-certified runs. The true value emerged in energy savings: **EEE mode** reduced annual power costs by $18K per module. In an era chasing multi-gig speeds, this hardware teaches that infrastructure readiness determines success more than headline specs.