​Technical Specifications and Compliance​

The Cisco PWR-4430-AC= is a ​​4,430-watt AC power supply​​ designed for high-density data center and enterprise environments. Engineered to deliver reliable power with ​​94% efficiency​​ (80 PLUS Platinum certified), it supports critical infrastructure with the following specifications:

  • ​Input Voltage​​: 200–240V AC, 50/60Hz
  • ​Output​​: 12V DC, 369A max current
  • ​Redundancy​​: Supports N+1, N+N configurations
  • ​Compliance​​:
    • ​NEBS Level 3​​ (GR-63-CORE seismic/vibration)
    • ​UL 60950-1​​ (Safety)
    • ​RoHS 3​​ (EU 2015/863)
  • ​Environmental​​:
    • Operating Temperature: 0°C to 45°C (derate 2% per °C above 40°C)
    • MTBF: 250,000 hours (MIL-HDBK-217F)

​Comparison with Previous Models​

Parameter PWR-4430-AC= PWR-4KW-AC=
Efficiency 94% 92%
Redundancy Support N+1, N+N N+1 only
Output Ripple <50mV <75mV

​Compatibility and Integration​

​Supported Cisco Platforms​

  • ​Switches​​: Nexus 9504/9508 with N9K-PUV4 chassis
  • ​Servers​​: UCS C480 ML M5 (requires UCSX-PSU-4300AC= adapter)
  • ​Routers​​: ASR 9904 with A9K-PWR-4KW= module

​Third-Party Validation​

  • Validated with ​​NVIDIA DGX A100​​ systems via Cisco UCS C-Series racks
  • Requires firmware updates for ​​Juniper QFX5200​​ (Junos 21.2R3+)

​Installation and Redundancy Configuration​

​Step-by-Step Deployment​

  1. ​Safety Precautions​​: Ensure AC circuit breakers are locked out (NFPA 70E compliance).
  2. ​Mounting​​: Slide PSU into chassis slot until latch clicks (tool-less design).
  3. ​Power Redundancy​​: Configure via Cisco NX-OS CLI:
    power redundancy-mode combined  
    power supply 1 priority primary  

​Thermal Management​

  • Maintain ≥5cm clearance between PSUs for optimal airflow.
  • Monitor temperatures via show environment power (alarm triggers at 50°C).

​Addressing Critical Deployment Concerns​

​Q: How does load balancing work across multiple PSUs?​

  • ​Dynamic Load Sharing​​: Automatically distributes load proportionally (e.g., 60/40 split during peak).
  • ​Manual Override​​: Use power supply priority CLI commands for critical modules.

​Q: What is the procedure during a PSU failure?​

  • ​Hot-Swap Replacement​​: Remove faulty unit within 2 minutes; replacement auto-syncs with existing config.
  • ​Alerts​​: SNMP traps sent via Cisco UCS Manager or Nexus Dashboard.

​Q: Mitigating harmonic distortion?​

  • ​Power Factor Correction (PFC)​​: 0.99 PF rating minimizes grid feedback.
  • ​Deploy Active Filters​​: Use Cisco CAB-AC-FILTER= for environments with sensitive equipment.

​Maintenance and Lifecycle Management​

​Firmware Updates​

  • ​NX-OS​​: 10.2(3)F+ for adaptive current sharing.
  • ​UCS Manager​​: 4.3(1c)+ for predictive failure analytics.

​End-of-Life Strategy​

  • ​Last RMA Date​​: Q3 2031 (Cisco EOL Notice #7845).
  • ​Recycling​​: Separate aluminum heat sinks from PCBs per R2v3 standards.

​Operational Insights from Healthcare Deployments​
In a regional hospital’s data center, deploying 8x PWR-4430-AC= units reduced unplanned downtime by ​​92%​​ over 18 months. While 48V DC architectures gain traction, this PSU’s ​​N+N redundancy​​ ensured uninterrupted EHR access during grid fluctuations. The unexpected benefit? Its ​​low ripple output​​ (<50mV) eliminated data corruption in MRI imaging storage—proving that power quality directly impacts clinical outcomes.

For procurement and compatibility checks: [“PWR-4430-AC=” link to (https://itmall.sale/product-category/cisco/).

Related Post

CP-7841-3PCC-K9++=: How Does This Cisco Bundl

Overview of the CP-7841-3PCC-K9++= The ​​CP-7841-3P...

NC57-48Q2D-BM: How Does Cisco\’s Quantu

Core Architecture: Adaptive Threat Processing Engine Th...

UCSX-210C-M6-CH Modular Chassis: Architectura

​​UCSX-210C-M6-CH in Cisco’s X-Series Compute Arc...