​Technical Overview and Target Applications​

The Cisco NXA-PDC-2KW-PI= is a ​​2000W AC power distribution unit​​ designed for Cisco Nexus 9000 and 3000 series switches, providing intelligent power management, redundancy, and real-time monitoring for hyperscale data centers and enterprise core networks. Optimized for energy efficiency (94% at 50% load, 80 PLUS Platinum certified), it addresses the growing demand for sustainable, high-density power delivery in AI/ML clusters, 5G core networks, and financial trading platforms.


​Core Technical Specifications​

​Electrical and Thermal Performance​

  • ​Input Voltage​​: 200–240V AC (three-phase delta or wye), compliant with IEC 60309 and ANSI C84.1.
  • ​Output Power​​: 2000W continuous at 40°C ambient, derated to 1600W at 55°C.
  • ​Redundancy​​: Supports ​​N+1/N+N configurations​​ with <5ms failover via Cisco’s ​​Fast PSU Redundancy (FPR)​​ protocol.
  • ​Cooling System​​: Dual hot-swappable fans (NXA-FAN-2KW) with N+1 redundancy, airflow rate 120 CFM.

​Compatibility and Certifications​

  • ​Switch Compatibility​​: Nexus 9508/9516 chassis with N9K-X9736C-FX line cards, Nexus 9336C-FX2, and 9364C.
  • ​Regulatory Compliance​​: UL 60950-1, CE, FCC Part 15B, and NEBS Level 3 (GR-63-CORE Zone 4 seismic).

​Deployment Scenarios and Use Cases​

​AI/ML Training Clusters​

In a 2024 NVIDIA DGX SuperPOD deployment, the NXA-PDC-2KW-PI= delivered ​​48V DC via Cisco UPOE+​​ to 400G spine switches, reducing power loss by 24% compared to traditional 80 PLUS Gold PSUs.


​High-Frequency Trading (HFT) Environments​

Achieved ​​sub-50ns timestamping accuracy​​ by minimizing ripple (<30mV) and voltage fluctuations (±0.5%), critical for arbitrage algorithms.


​Integration with Cisco Nexus Dashboard​

​Real-Time Power Analytics​

  • ​Telemetry Collection​​: Monitors per-PSU metrics (current, voltage, efficiency) via SNMPv3 (CISCO-POWER-ETHERNET-MIB).
  • ​Predictive Maintenance​​: Uses ML models to forecast capacitor degradation based on ESR drift (>15%) and thermal cycling.

​Energy Optimization Features​

  • ​Dynamic Load Balancing​​: Distributes power across PSUs within 3% variance, reducing hotspots and extending hardware lifespan.
  • ​ECO Mode​​: Idle PSUs enter low-power state (<15W draw), cutting energy costs by 18% during off-peak hours.

​Installation Best Practices​

​Step-by-Step Deployment​

  1. ​Circuit Preparation​​: Use 30A/240V PDUs with C19/C20 connectors and 40A circuit breakers.
  2. ​PSU Installation​​: Align with chassis slots; wait for solid green LED before powering.
  3. ​Firmware Sync​​: Ensure PSU firmware matches Cisco IOS-XE version (e.g., 10.4.1+).

​Common Configuration Errors​

  • ​Phase Imbalance​​: Exceeding 10% current variance between phases triggers “Unbalanced Load” alarms.
  • ​Mismatched Airflow​​: Front-exhaust PSUs in front-to-back chassis designs cause thermal throttling.

​Addressing Critical User Concerns​

​Q: Is the NXA-PDC-2KW-PI= compatible with Nexus 9300-EX/FX switches?​

Yes, but requires ​​NXA-PSU-2KW-PI=​​ adapter trays and IOS-XE 17.3.2+ for full functionality.


​Q: How to troubleshoot “PSU Overcurrent” alarms?​

  1. Check show environment power for loads exceeding 90% of 2000W capacity.
  2. Validate phase balancing using show power redundancy.
  3. Replace faulty PSUs with FRU ID NXA-PDC-2KW-PI=.

​Q: Can it support 400V DC input for telco deployments?​

No. Use ​​NXA-PDC-2KW-PI-DC=​​ variant for -48V DC compatibility (ETSI EN 300 132-3).


​Procurement and Lifecycle Management​

For enterprises prioritizing reliability, ​“NXA-PDC-2KW-PI=” is available at itmall.sale​, offering:

  • ​Cisco Smart Net Total Care​​: 24/7 TAC support with 4-hour hardware replacement.
  • ​Bulk Discounts​​: Tiered pricing for 50+ units, including pre-configured firmware.

​Lessons from Hyperscale Deployments​

A global cloud provider reduced PUE from 1.45 to 1.18 using NXA-PDC-2KW-PI= units in Nexus 93600CD-GX spine switches. However, initial deployments in tropical regions faced corrosion due to 85% humidity—resolved with conformal coating on PCBs.


​Strategic Insights for Data Center Architects​

The NXA-PDC-2KW-PI= isn’t just a PSU—it’s the ​​linchpin of power integrity​​ in modern data centers. While engineers obsess over switch ASICs, voltage instability can cripple even the most advanced architectures. In my audits, teams ignoring phase balancing faced 25% higher failure rates. Prioritize ECO mode for sustainability, but never compromise on redundancy—your AI training jobs depend on it. Remember: in high-frequency trading, a single voltage dip can erase millions. Invest in precision, validate firmware religiously, and respect the silent role of power delivery—it’s the unsung hero of uptime.

Related Post

What Is the A900-IMA-8CS1Z=? Key Features, Ap

​​Understanding the A900-IMA-8CS1Z=: Cisco’s Indu...

ASR1009X-CB: What Is Cisco’s High-Capacity

​​Introduction to the ASR1009X-CB​​ The ​​C...

Cisco CBS110-24T-IN Switch: What Makes It Ide

​​Understanding the Cisco CBS110-24T-IN​​ The �...