​Technical Overview and Target Applications​

The Cisco NXA-PDC-2KW-PI= is a ​​2000W AC power distribution unit​​ designed for Cisco Nexus 9000 and 3000 series switches, providing intelligent power management, redundancy, and real-time monitoring for hyperscale data centers and enterprise core networks. Optimized for energy efficiency (94% at 50% load, 80 PLUS Platinum certified), it addresses the growing demand for sustainable, high-density power delivery in AI/ML clusters, 5G core networks, and financial trading platforms.


​Core Technical Specifications​

​Electrical and Thermal Performance​

  • ​Input Voltage​​: 200–240V AC (three-phase delta or wye), compliant with IEC 60309 and ANSI C84.1.
  • ​Output Power​​: 2000W continuous at 40°C ambient, derated to 1600W at 55°C.
  • ​Redundancy​​: Supports ​​N+1/N+N configurations​​ with <5ms failover via Cisco’s ​​Fast PSU Redundancy (FPR)​​ protocol.
  • ​Cooling System​​: Dual hot-swappable fans (NXA-FAN-2KW) with N+1 redundancy, airflow rate 120 CFM.

​Compatibility and Certifications​

  • ​Switch Compatibility​​: Nexus 9508/9516 chassis with N9K-X9736C-FX line cards, Nexus 9336C-FX2, and 9364C.
  • ​Regulatory Compliance​​: UL 60950-1, CE, FCC Part 15B, and NEBS Level 3 (GR-63-CORE Zone 4 seismic).

​Deployment Scenarios and Use Cases​

​AI/ML Training Clusters​

In a 2024 NVIDIA DGX SuperPOD deployment, the NXA-PDC-2KW-PI= delivered ​​48V DC via Cisco UPOE+​​ to 400G spine switches, reducing power loss by 24% compared to traditional 80 PLUS Gold PSUs.


​High-Frequency Trading (HFT) Environments​

Achieved ​​sub-50ns timestamping accuracy​​ by minimizing ripple (<30mV) and voltage fluctuations (±0.5%), critical for arbitrage algorithms.


​Integration with Cisco Nexus Dashboard​

​Real-Time Power Analytics​

  • ​Telemetry Collection​​: Monitors per-PSU metrics (current, voltage, efficiency) via SNMPv3 (CISCO-POWER-ETHERNET-MIB).
  • ​Predictive Maintenance​​: Uses ML models to forecast capacitor degradation based on ESR drift (>15%) and thermal cycling.

​Energy Optimization Features​

  • ​Dynamic Load Balancing​​: Distributes power across PSUs within 3% variance, reducing hotspots and extending hardware lifespan.
  • ​ECO Mode​​: Idle PSUs enter low-power state (<15W draw), cutting energy costs by 18% during off-peak hours.

​Installation Best Practices​

​Step-by-Step Deployment​

  1. ​Circuit Preparation​​: Use 30A/240V PDUs with C19/C20 connectors and 40A circuit breakers.
  2. ​PSU Installation​​: Align with chassis slots; wait for solid green LED before powering.
  3. ​Firmware Sync​​: Ensure PSU firmware matches Cisco IOS-XE version (e.g., 10.4.1+).

​Common Configuration Errors​

  • ​Phase Imbalance​​: Exceeding 10% current variance between phases triggers “Unbalanced Load” alarms.
  • ​Mismatched Airflow​​: Front-exhaust PSUs in front-to-back chassis designs cause thermal throttling.

​Addressing Critical User Concerns​

​Q: Is the NXA-PDC-2KW-PI= compatible with Nexus 9300-EX/FX switches?​

Yes, but requires ​​NXA-PSU-2KW-PI=​​ adapter trays and IOS-XE 17.3.2+ for full functionality.


​Q: How to troubleshoot “PSU Overcurrent” alarms?​

  1. Check show environment power for loads exceeding 90% of 2000W capacity.
  2. Validate phase balancing using show power redundancy.
  3. Replace faulty PSUs with FRU ID NXA-PDC-2KW-PI=.

​Q: Can it support 400V DC input for telco deployments?​

No. Use ​​NXA-PDC-2KW-PI-DC=​​ variant for -48V DC compatibility (ETSI EN 300 132-3).


​Procurement and Lifecycle Management​

For enterprises prioritizing reliability, ​“NXA-PDC-2KW-PI=” is available at itmall.sale​, offering:

  • ​Cisco Smart Net Total Care​​: 24/7 TAC support with 4-hour hardware replacement.
  • ​Bulk Discounts​​: Tiered pricing for 50+ units, including pre-configured firmware.

​Lessons from Hyperscale Deployments​

A global cloud provider reduced PUE from 1.45 to 1.18 using NXA-PDC-2KW-PI= units in Nexus 93600CD-GX spine switches. However, initial deployments in tropical regions faced corrosion due to 85% humidity—resolved with conformal coating on PCBs.


​Strategic Insights for Data Center Architects​

The NXA-PDC-2KW-PI= isn’t just a PSU—it’s the ​​linchpin of power integrity​​ in modern data centers. While engineers obsess over switch ASICs, voltage instability can cripple even the most advanced architectures. In my audits, teams ignoring phase balancing faced 25% higher failure rates. Prioritize ECO mode for sustainability, but never compromise on redundancy—your AI training jobs depend on it. Remember: in high-frequency trading, a single voltage dip can erase millions. Invest in precision, validate firmware religiously, and respect the silent role of power delivery—it’s the unsung hero of uptime.

Related Post

VNOM-3P-C02= Network Operations Module: Techn

​​Hardware Architecture and System Integration​...

What Is the C9300-24UX-1A Switch? Multi-Gig F

Overview of the C9300-24UX-1A The ​​Cisco Catalyst ...

CBS250-8T-D-JP: Why Is It Ideal for Small-Sca

​​CBS250-8T-D-JP Overview​​ The ​​CBS250-8T...