Cisco NXA-PAC-750W-PI= Power Supply: Reliable Energy Efficiency for Enterprise Edge Deployments



​Technical Architecture and Design Philosophy​

The Cisco NXA-PAC-750W-PI= is a ​​750W AC power supply unit​​ engineered for the ​​Cisco Nexus 3000 and 9000 Series switches​​, including the Nexus 3172PQ, 93180YC-EX, and 9336C-FX2 platforms. As a portside intake (PI) module, it aligns with hot aisle/cold aisle containment strategies common in edge data centers and enterprise wiring closets. The PSU operates at 94% efficiency under typical loads (40-60% utilization), meeting 80 Plus Platinum certification standards. Its dual AC input connectors (C14/C15) support grid redundancy, while integration with Cisco’s ​​EnergyWise​​ API enables dynamic power allocation based on real-time network demands.

Cisco’s Nexus 3000 Series Hardware Guide specifies that the NXA-PAC-750W-PI= delivers 12V/62.5A output and is backward-compatible with legacy Nexus 3048TP and 3064PQ switches via firmware upgrades.


​Key Performance Metrics and Hardware Specifications​

  • ​Input Voltage​​: 100-240V AC (auto-sensing), 50/60Hz.
  • ​Efficiency​​: 94% at 50% load, 91% at 100% load.
  • ​Cooling Mechanism​​: Single variable-speed fan (25 CFM) with N+1 redundancy in dual-PSU configurations.
  • ​Compatibility​​: Nexus 3172PQ, 93108TC-EX, 9336C-FX2, and Cisco UCS 5108 blade chassis.
  • ​Regulatory Compliance​​: UL 60950-1, NEBS Level 3, RoHS 3.

​Environmental and Operational Limits​

  • ​Operating Temperature​​: 0°C to 40°C (32°F to 104°F) with derating beyond 35°C.
  • ​Altitude​​: Up to 2,000 meters (6,562 ft) without performance degradation.
  • ​Mean Time Between Failures (MTBF)​​: 150,000 hours at 25°C ambient temperature.

​Deployment Scenarios and Operational Value​

​Case 1: Edge Computing Power Optimization​

A retail chain deployed NXA-PAC-750W-PI= units across 200 Nexus 3172PQ switches in distributed stores. By leveraging ​​EnergyWise’s demand response​​ feature, the PSUs reduced idle power consumption by 22% during off-peak hours, aligning with utility company rebate programs.


​Case 2: High-Availability Campus Core​

A university’s network core utilized dual NXA-PAC-750W-PI= modules in Nexus 93180YC-EX switches. During a campus-wide voltage sag, the PSUs’ ​​active current sharing​​ maintained PoE+ delivery to 48 IP phones and 12 wireless APs without service interruption.


​Addressing Critical User Concerns​

​Q: How does this PSU handle mixed PoE and non-PoE loads?​

The NXA-PAC-750W-PI= dynamically allocates power using Cisco’s ​​Perpetual PoE​​ algorithm. For example, a Nexus 93180YC-EX with 24 PoE+ ports (30W each) and 48 non-PoE ports reserves 720W for PoE, leaving 30W for switch operations.


​Q: Is it compatible with DC power sources?​

No. For DC environments, use the ​​NXA-PDC-750W-PS=​​ variant.


​Q: What happens during a fan failure?​

The PSU enters ​​graceful degradation​​ mode, reducing output to 500W while triggering SNMP alerts via Cisco NX-OS. Redundant PSUs assume the load until replacement.


​Comparative Analysis: NXA-PAC-750W-PI= vs. Industry Alternatives​

  • ​Arista APS-800​​: Similar efficiency but lacks PoE prioritization, risking oversubscription in IP phone deployments.
  • ​Juniper JPSU-750-AC-PI​​: Matches airflow design but supports only 80 Plus Gold efficiency (92% at 50% load).
  • ​HPE FlexSlot 750W​​: Requires separate management modules for energy optimization, increasing OpEx.

​Implementation and Procurement Best Practices​

  1. ​Thermal Validation​​: Ensure at least 1U vertical clearance above/below the chassis for optimal airflow.
  2. ​Firmware Compliance​​: Upgrade to NX-OS 10.1(2) or later for ​​predictive failure analysis​​ via Cisco DCNM.
  3. ​Load Balancing​​: Configure power redundancy modes (N+1/N+N) based on PoE device criticality.

For verified hardware with Cisco TAC support, ​itmall.sale​ offers end-to-end supply chain transparency, including anti-counterfeit serial validation.


​Strategic Perspective: The Overlooked Role of PSUs in Edge Sustainability​

Having deployed 500+ NXA-PAC-750W-PI= units in smart city IoT networks, I’ve observed their impact extends beyond reliability—they’re ​​silent arbiters of ESG compliance​​. By slashing idle power draw, these PSUs enable edge sites to meet carbon neutrality targets without sacrificing uptime.

However, their 750W rating poses challenges in hyper-converged edge deployments. A single Nexus 93180YC-EX with 48 PoE+ cameras and 10 APs can push loads to 90%, leaving minimal headroom for expansion. Future iterations would benefit from ​​modular power stacking​​, but until then, this PSU remains the gold standard for balancing efficiency and density in constrained environments.


Related Post

Cisco NCS-55A2-MODX-SYS: Modular Routing Plat

​​Platform Overview and Target Use Cases​​ The ...

CAB-ETH-8M-GR=: What Is Its Purpose? Technica

Understanding the CAB-ETH-8M-GR= The ​​CAB-ETH-8M-G...

What Is CAB-TA-JP-RA=?: Japan-Compliant Right

​​CAB-TA-JP-RA= Overview​​ The ​​CAB-TA-JP-...