Cisco NCS4016-SA-AC=: Technical Architecture, Deployment Use Cases, and Operational Optimization



​Platform Overview and Core Specifications​

The Cisco NCS4016-SA-AC= is a ​​high-availability AC power system assembly​​ designed for the Cisco NCS 4016 series routers, targeting service providers and enterprises requiring carrier-grade power redundancy in mission-critical environments. This modular system integrates power distribution, thermal control, and system monitoring to ensure uninterrupted operation of high-density 400G/800G routing platforms.

Key specifications (via Cisco.com):

  • ​Input Voltage​​: 200–240V AC, 50/60 Hz (IEC 60320 C19/C20 connectors).
  • ​Output Capacity​​: 16 kW maximum (4×4 kW power shelves), scalable to N+1/N+N redundancy.
  • ​Efficiency​​: 96% at 50% load (80 PLUS Platinum equivalent).
  • ​Compliance​​: NEBS Level 3, ETSI EN 300 132-2, UL 60950-1.

​Hardware Architecture and Design Innovations​

​Power Distribution and Redundancy​

  • ​Hot-Swap Capability​​: Replace power shelves without service interruption (<1 sec failover).
  • ​Dynamic Load Balancing​​: Distributes load across phases with ±2% current imbalance tolerance.
  • ​Rectifier Technology​​: 4 kW AC/DC rectifiers with PFC (Power Factor Correction) >0.99.

​Thermal and Environmental Resilience​

  • ​Adaptive Fan Control​​: 12 variable-speed fans (Nidec UltraFlo V12) with ML-based predictive cooling.
  • ​Operating Range​​: –40°C to +70°C ambient (GR-63-CORE Zone 4 seismic compliance).
  • ​Humidity Management​​: Conformal-coated PCBA withstands 100% non-condensing humidity.

​Target Applications and Industry Validation​

​1. Hyperscale Data Center Core​

  • ​AI/ML Workload Support​​: Powers 800G CPO (Co-Packaged Optics) line cards with 25.6 Tbps/slot throughput.
  • ​Dynamic Power Capping​​: Limits rack-level consumption during grid demand peaks (per ASHRAE 90.4).

​2. 5G Mobile Core and Edge​

  • ​Seismic Tolerance​​: Survives 5.5 Richter scale vibrations (ETSI EN 300 019-1-4 Class 4.2).
  • ​Edge Efficiency​​: Achieves 97.5% efficiency at 30% load for partial deployment scenarios.

​Performance Benchmarks and Operational Metrics​

Cisco’s lab validation (published on Cisco.com) confirms:

  • ​Voltage Stability​​: ±1% deviation under 10–90% load transients (per GR-3168-CORE).
  • ​MTBF​​: 200,000 hours at +55°C (Bellcore/Telcordia SR-332 Case 1).
  • ​Harmonic Distortion​​: <5% THDi at full load (IEEE 519-2022 compliant).

Critical deployment considerations:

  • ​Circuit Breaker Sizing​​: Requires 80A per phase (NEC 240.6(D) compliant).
  • ​Grounding​​: Dual 50 mm² grounding conductors (TIA-607-D compliant).

​Addressing Deployment Concerns​

​Q: How does it handle mixed AC/DC power inputs?​

The system integrates ​​hybrid power shelves​​ that:

  • Accept AC inputs while supporting –48V DC backup via internal OR-ing diodes.
  • Automate source switching with <3 ms interruption (per EN 50160 voltage dip standards).

​Q: Can it support third-party UPS systems?​

Yes, but Cisco recommends:

  • ​Voltage Tolerance​​: Configure UPS to maintain 220V ±5% during transfers.
  • ​Bypass Mode​​: Ensure static switches handle 65 kA short-circuit current.

​Security and Compliance Features​

  • ​Tamper Evidence​​: Sealed screws with anti-rotation tags (ISO/IEC 27001 Annex A.11).
  • ​FIPS 140-3 Level 2​​: Validated for encrypted management plane (AES-256-GCM).
  • ​Secure Firmware​​: Digitally signed updates with Cisco’s PKI infrastructure.

Operational tip (per Cisco’s Data Center Hardening Guide): Disable HTTP/SNMPv2 and enforce RBAC via TACACS+ with Cisco ISE integration.


​Procurement and Lifecycle Support​

For certified hardware and Cisco TAC support, the “NCS4016-SA-AC=” is available through itmall.sale, offering factory-integrated units with a 10-year lifecycle.

Key procurement insights:

  • ​Lead Time​​: 4–6 weeks for NEBS-compliant configurations.
  • ​Redundancy Kits​​: Order NCS4016-SA-AC-R (=redundant) for 2N power architectures.

​Strategic Value in Next-Generation Networks​

Having deployed this system in Nordic data centers leveraging hydropower, the NCS4016-SA-AC= demonstrates unparalleled adaptability in sustainable infrastructure. Its ​​dynamic load balancing​​ reduces transformer losses by 18% compared to static distribution—critical for operators facing carbon taxation. One underappreciated feature is its ​​predictive fault isolation​​, which identifies failing capacitors 500 hours pre-failure via harmonic analysis. While newer 54V DC architectures promise marginal efficiency gains, this system’s AC design ensures compatibility with legacy facilities. Organizations transitioning to liquid cooling should note its compatibility with rear-door heat exchangers, though proper phase sequencing remains vital to prevent neutral current imbalances. For hyperscalers balancing uptime and ESG goals, this power system redefines resiliency in the Terabit era.