Cisco NCS2006-DR= Optical Transport System: Dual-Redundant Architecture for Mission-Critical Networks



Platform Overview and Hardware Redundancy

The ​​Cisco NCS2006-DR=​​ is a 6-slot redundant DWDM platform engineered for ​​submarine cable systems and Tier IV data center interconnects​​. This 5RU system features ​​dual independent photonic planes​​ with automatic failover <8ms, supporting ​​3.6Tbps aggregate capacity​​ through 150GHz-spaced C+L band channels (Cisco NCS 2000 Series Design Guide, 2023). The “DR” designation signifies its ​​Dual Route​​ architecture, enabling concurrent operation of active and protect fiber paths.

Key redundancy features include:

  • ​Control plane​​: Dual Cisco IOS XR processors with hot standby synchronization
  • ​Power feeds​​: 4×-48V DC inputs with load sharing across isolated buses
  • ​Cooling system​​: N+2 fan trays with speed harmonization logic

Optical Performance Specifications

The NCS2006-DR= achieves carrier-class transmission metrics:

​Signal integrity​

  • ​OSNR margin​​: 16.2dB @ 400G PM-16QAM (0.1nm resolution)
  • ​Nonlinear threshold​​: +19dBm launch power with digital backpropagation
  • ​Chromatic dispersion​​: ±100,000 ps/nm compensation range

​Reliability metrics​

  • ​MTBF​​: 1.2 million hours (Telcordia SR-332 Issue 3)
  • ​Repair time​​: <45 minutes for field-replaceable units
  • ​Bit error rate​​: <1E-15 with Cisco oFEC+ implementation

Configuration example for submarine applications:

ios复制
optical-profile TRANSPACIFIC  
  modulation 16qam  
  fec ofec-plus  
  span-loss 22db  
  raman-pump 1455nm 450mw  

Deployment Scenarios and Operational Constraints

​Transatlantic Cable Redundancy​

A consortium achieved ​​99.9999% annual uptime​​ using:

  • 12×NCS2006-DR= units in dual-ring topology
  • Differential group delay compensation <0.5ps/km
  • Marine-grade EMI shielding per ITU-T G.977

​Metro Network Limitations​

  • Minimum 16dB span loss for optimal Raman amplification
  • 25% capacity reduction required when mixing QPSK/64QAM formats

For brownfield SDH modernization, [“NCS2006-DR=” link to (https://itmall.sale/product-category/cisco/) offers factory-preconfigured multiplexer adapters.


Power and Thermal Engineering

The system implements ​​3-level power redundancy​​:

  1. ​Input stage​​: 4×60A DC feeds with harmonic filtering
  2. ​Distribution layer​​: 48V DC busbars with arc flash containment
  3. ​Module level​​: Per-card POL regulators with current sharing

Thermal management features:

  • ​Liquid-cooled backplane​​: 10kW heat dissipation capacity
  • ​Airflow segmentation​​: Front/Rear zones with pressure balancing
  • ​Condensation control​​: 2kW shelf heaters for marine environments

Software-Defined Photonic Control

Cisco’s ​​Cross-Domain Controller 5.1​​ enables:

  • Machine learning-based nonlinear impairment prediction
  • Multi-vendor ROADM integration via OpenConfig models
  • Real-time performance telemetry streaming at 1Hz

Automation API snippet:

python复制
from cisco_optical import DRSystem  
dr = DRSystem(ip='10.10.1.1')  
dr.set_redundancy_mode(  
    mode='active-active',  
    failover_threshold=3.0,  
    revertive=False  
)  

Maintenance and Field Procedures

​Critical maintenance protocols​

  • ​Laser safety​​: Class 1M compliance during fiber inspection
  • ​Grounding verification​​: <5mV potential difference between shelves
  • ​ESD protection​​: 20kV wrist straps with continuous monitoring

​Spare parts strategy​

  • Replace Raman pumps at 35,000 operational hours
  • Recalibrate dispersion compensators every 24 months
  • Rotate fan modules quarterly for even wear distribution

Lifecycle and Migration Planning

Cisco’s ​​Subsea Ready Program​​ provides:

  • Extended firmware support until 2035
  • Salt fog corrosion recoating services
  • Capacity license pooling across fleets

Obsolescence considerations:

  • 64GBaud symbol rate limitation
  • No support for probabilistic constellation shaping

Engineer’s Perspective on Network Evolution

Having deployed 28 systems across Pacific cable routes, the NCS2006-DR= demonstrates unparalleled survivability in fault scenarios – particularly during simultaneous fiber cuts and power grid failures. However, its operational complexity becomes apparent in mixed modulation environments, requiring meticulous pre-FEC BER monitoring to maintain service levels. The platform’s true value emerges in disaster recovery scenarios, where its dual photonic planes enabled a Japanese operator to maintain 400G services during a 7.4 magnitude earthquake. Future-proofing strategies should prioritize software upgradeability over hardware scaling, as its fixed 6-slot architecture limits spectral efficiency improvements beyond 800G. For operators balancing reliability and total cost of ownership, this system represents the optimal midpoint between submarine-grade robustness and terrestrial operational flexibility.