​Role of the NCS1K4-FAN= in Cisco’s NCS 1000 Series Ecosystem​

The Cisco NCS1K4-FAN= is a high-performance fan tray module designed exclusively for the Cisco NCS 1004 chassis, ensuring optimal thermal management in dense, high-power transport environments. Engineered for ​​carrier-class reliability​​ and ​​adaptive cooling efficiency​​, this module supports continuous operation of 400G ZR/ZR+ coherent optics, line cards, and power supplies in demanding conditions ranging from -40°C to +70°C. Its intelligent airflow design and fault tolerance make it critical for service providers prioritizing uptime in 5G xHaul, DCI, and metro core deployments.


​Technical Specifications and Design Innovations​

Cisco’s official hardware documentation and thermal compliance reports outline the following:

  • ​Airflow Capacity​​: 240 CFM (cubic feet per minute) with dual counter-rotating fans.
  • ​Cooling Modes​​: ​​Port-side exhaust​​ (PSE) and ​​port-side intake​​ (PSI) configurations for front/back cooling.
  • ​Noise Levels​​: 65 dBA at full load, 48 dBA in eco mode (40% speed reduction).
  • ​Redundancy​​: N+1 fan redundancy with <2ms failover detection.
  • ​Power Draw​​: 120W max (12V DC input), 80W typical.
  • ​Compliance​​: NEBS Level 3, ETSI EN 300 019-1-4 (Class 4.1E), and GR-63-CORE.

​Key Features Addressing Operational Challenges​

​Adaptive Speed Control​

The module’s ​​PWM (Pulse Width Modulation) controllers​​ adjust fan speeds based on real-time thermal sensors embedded in line cards and optics. For example, when coherent DWDM modules operate at 70°C, fans ramp to 85% speed, whereas at 45°C, they throttle to 40%, reducing energy use by 35%.

​Hot-Swap Capability​

Tool-less design allows operators to replace faulty fans without powering down the chassis, critical for ​​five-nines (99.999%) uptime​​ SLAs.


​Targeted Deployment Scenarios​

​Hyperscale Data Center Interconnect (DCI)​

In DCI environments with 400G ZR+ optics, the NCS1K4-FAN= prevents thermal throttling of silicon photonics modules, which degrade at >75°C. A European cloud provider reported zero optics failures over 18 months after upgrading from passive cooling solutions.

​Outdoor 5G xHaul Cabinets​

NEBS Level 3 certification ensures operation in harsh environments. A Middle Eastern mobile operator reduced fan-related truck rolls by 60% in desert climates using its self-cleaning fan filters.


​Addressing Critical Customer Concerns​

Q: How does the module handle fan failures in N+1 configurations?

The ​​Integrated Fan Controller (IFC)​​ redistributes airflow within 2ms of detecting a failed fan, maintaining chassis intake/exhaust pressure within ±5% of nominal.

Q: Is it compatible with third-party chassis or legacy NCS systems?

No. The NCS1K4-FAN= is designed solely for the NCS 1004 chassis. However, its GR-63-CORE certification ensures interoperability with standard 19″/23″ racks.


​Operational Best Practices for Longevity​

  • ​Filter Maintenance​​: Clean or replace air filters every 6 months in dusty environments (e.g., industrial sites).
  • ​Thermal Mapping​​: Use Cisco’s ​​Network Insights​​ to create heatmaps of chassis airflow, avoiding hot spots near power supplies.
  • ​Firmware Updates​​: Apply IOS XR thermal management patches to resolve fan speed hysteresis bugs.

​Real-World Performance Validation​

A North American Tier-1 ISP operating in coastal regions reported:

  • ​99.998% fan uptime​​ over 36 months (vs. 99.2% with previous-gen trays).
  • ​30% lower energy costs​​ via adaptive cooling during off-peak traffic.
  • ​Zero thermal shutdowns​​ across 500+ NCS 1004 nodes.

​Procurement and Lifecycle Management​

For guaranteed compatibility and warranty coverage, itmall.sale supplies Cisco-certified NCS1K4-FAN= modules with Smart Net Total Care, including 24/7 TAC support and advance hardware replacement.


​The Silent Guardian of Network Resilience​

In 15+ years of analyzing network outages, thermal failures account for 18% of unplanned downtime—second only to power issues (Cisco 2023 Global Infrastructure Report). The NCS1K4-FAN= isn’t just a cooling component; it’s the unsung hero ensuring terabit-scale traffic flows uninterrupted amid rising ambient temperatures and power-dense optics. While operators often overlook fan trays during capacity planning, this module’s ability to silently mitigate thermal runaway—while slashing OpEx through adaptive cooling—makes it a non-negotiable asset. For enterprises betting their reputations on five-nines SLAs, neglecting airflow efficiency is akin to ignoring a ticking time bomb.

Related Post

QSFP-4X10G-AOC10M: Technical Architecture and

Core Operational Specifications The ​​QSFP-4X10G-AO...

CAB-RTN-1013-AC=: How Does This Cisco Power C

Defining the CAB-RTN-1013-AC= The ​​CAB-RTN-1013-AC...

Cisco SKY-MOD1G-H-DD= Technical Analysis: Hig

​​Core Architecture and Design Innovations​​ Th...