A9KV-V2-DC-E=: How Does Cisco’s Enhanced Module Optimize Data Center Interconnect Performance?



​Defining the A9KV-V2-DC-E=​

The ​​A9KV-V2-DC-E=​​ is a ​​high-density, multi-rate line card​​ engineered for Cisco’s ASR 9000 Series routers, specifically targeting ​​hyperscale data center interconnect (DCI)​​ and ​​cloud exchange deployments​​. Designed as an evolution of the V1 model, this module supports ​​mixed-speed port configurations​​ (10G/25G/40G/100G) and integrates advanced telemetry features to meet the demands of dynamic, high-throughput environments like AI fabric backbones or multi-cloud gateways.


​Technical Innovations and Specifications​

  • ​Port Density​​: ​​36x QSFP28/56 slots​​ with ​​breakout support​​ for 100G to 4x25G or 40G to 4x10G, enabling flexible topology design.
  • ​Throughput​​: ​​3.6 Tbps per slot​​, leveraging Cisco’s ​​Chiplet ASIC​​ for deep buffer management and lossless transport.
  • ​Energy Efficiency​​: ​​20% lower power consumption​​ than the A9KV-V1-DC-E= via adaptive voltage scaling and sleep modes.
  • ​Telemetry​​: Embedded ​​In-band Network Telemetry (INT)​​ and ​​gRPC model-driven streaming​​, critical for real-time congestion visibility.
  • ​Security​​: Hardware-based ​​MACsec-256​​ encryption at line rate for all port speeds, compliant with FIPS 140-3.

​A9KV-V2-DC-E= vs. A9KV-V1-DC-E=: Critical Improvements​

​Feature​ ​A9KV-V2-DC-E=​ ​A9KV-V1-DC-E=​
Port Flexibility 10G/25G/40G/100G 10G/40G/100G
Max Buffer per Port 64 MB 32 MB
Latency (Cut-Through) <750 ns <1.2 µs
Telemetry Granularity Per-flow INT Per-port SNMP
Encryption Overhead 0% 5% at 100G

This iteration targets ​​AI/ML workload scaling​​ and ​​hyperscaler DCI​​ where ​​microburst absorption​​ and ​​encryption transparency​​ are non-negotiable.


​Addressing Key Deployment Questions​

​Is the module backward-compatible with older ASR 9000 chassis?​

Yes, but it requires ​​IOS XR 7.10.1+​​ and a ​​minimum 3000W power shelf​​ for full performance. Legacy chassis (pre-2019) may need airflow retrofit kits.

​Can it interoperate with non-Cisco DCI solutions?​

Yes, via ​​standardized EVPN-VXLAN​​ or ​​SR-MPLS protocols​​, but features like INT require [“A9KV-V2-DC-E=” link to (https://itmall.sale/product-category/cisco/) optics for end-to-end visibility.

​How does it handle asymmetric traffic flows?​

The ​​Chiplet ASIC​​ employs ​​Dynamic Load Balancing (DLB)​​, redistributing traffic across underutilized paths to prevent congestion.

​What cooling is required for 100G full-duplex operation?​

Operates optimally at ​​10°C to 35°C​​ with ​​side-to-side airflow kits​​ mandatory in enclosed racks.


​Strategic Deployment Considerations​

The A9KV-V2-DC-E= isn’t just a hardware refresh—it’s a ​​capex multiplier​​ for data centers struggling with east-west traffic explosions. While its upfront cost is 30% higher than the V1, the ​​opex savings​​ from encryption offload and adaptive power can amortize costs within 18 months in 100G-heavy setups. For teams eyeing ​​liquid-cooled data centers​​, its thermal resilience (up to 45°C with auxiliary cooling) future-proofs investments. Pair it with ​​Cisco Nexus Dashboard​​ to automate fabric provisioning and avoid buffer bloat in AI training clusters.