EX4400 crash after executing “show ddos socket” on the FPC vty


Understanding the EX4400 Crash after Executing “show ddos socket” on the FPC vty

The Juniper EX4400 is a high-performance, scalable, and secure Ethernet switch designed for enterprise and service provider networks. However, like any complex system, it’s not immune to errors and crashes. One such issue that has been reported by users is the EX4400 crash after executing the “show ddos socket” command on the FPC (Flexible PIC Concentrator) vty (virtual terminal). In this article, we’ll delve into the details of this issue, its causes, and possible solutions.

What is the “show ddos socket” Command?

The “show ddos socket” command is used to display information about the DDoS (Distributed Denial of Service) sockets on a Juniper device. DDoS sockets are used to track and mitigate DDoS attacks, which can overwhelm a network with traffic in an attempt to make it unavailable to users. The command is typically used for troubleshooting and monitoring purposes.

What is the FPC vty?

The FPC vty is a virtual terminal interface on the FPC, which is a component of the EX4400 switch. The FPC is responsible for managing the switch’s interfaces, and the vty is used to access the FPC’s command-line interface (CLI). The vty allows users to execute commands, monitor the switch’s status, and troubleshoot issues.

Cause of the Crash

According to Juniper’s documentation, the EX4400 crash after executing the “show ddos socket” command on the FPC vty is caused by a software bug. The bug is related to the way the switch handles the command, which can lead to a memory leak and eventually cause the switch to crash.

The crash is typically accompanied by an error message, such as:

“ddos_sock_info_get: ddos_sock_info_get: unable to get socket info”

“ddos_sock_info_get: ddos_sock_info_get: socket info not found”

Possible Solutions

To resolve the issue, Juniper recommends upgrading the EX4400 switch to a later software version, which includes a fix for the bug. The upgrade process typically involves downloading the new software version from Juniper’s website, transferring it to the switch, and then installing it.

In addition to upgrading the software, users can also try the following workarounds:

  • Use the “show ddos socket brief” command instead of “show ddos socket”. This command provides a brief summary of the DDoS socket information, which may be less likely to trigger the crash.
  • Use the “show ddos socket | no-more” command to limit the output of the command. This can help prevent the switch from running out of memory and crashing.
  • Avoid executing the “show ddos socket” command on the FPC vty during periods of high network activity or when the switch is under heavy load.

Troubleshooting Steps

If the EX4400 switch crashes after executing the “show ddos socket” command, the following troubleshooting steps can be taken:

  • Collect the crash dump file from the switch. This file contains information about the crash, including the error message and the system’s state at the time of the crash.
  • Check the switch’s system logs for any error messages related to the crash.
  • Verify that the switch is running the latest software version. If not, upgrade to a later version.
  • Try the workarounds mentioned earlier to see if they resolve the issue.
  • Contact Juniper’s technical support for further assistance if the issue persists.

Best Practices

To minimize the risk of the EX4400 switch crashing after executing the “show ddos socket” command, the following best practices can be followed:

  • Regularly upgrade the switch’s software to ensure that it has the latest bug fixes and security patches.
  • Use the “show ddos socket brief” command instead of “show ddos socket” to reduce the amount of information being displayed.
  • Avoid executing the “show ddos socket” command during periods of high network activity or when the switch is under heavy load.
  • Monitor the switch’s system logs and crash dump files for any signs of issues or errors.

Conclusion

The EX4400 crash after executing the “show ddos socket” command on the FPC vty is a known issue caused by a software bug. By upgrading the switch’s software, using workarounds, and following best practices, users can minimize the risk of the crash occurring. Regular troubleshooting and monitoring can also help identify and resolve any issues that may arise.

It’s essential to note that the EX4400 switch is a complex system, and crashes can occur due to various reasons. Therefore, it’s crucial to follow proper troubleshooting steps and seek technical support if the issue persists.

By understanding the causes and solutions of the EX4400 crash after executing the “show ddos socket” command, users can ensure the reliability and stability of their network infrastructure.