​Architectural Design and Core Specifications​

The ​​Cisco VNOM-3P-V05=​​ is a three-phase AC/DC power supply unit designed for Cisco’s ​​Nexus 9000 Series switches​​, providing reliable power delivery in enterprise and hyperscale environments. Key specifications include:

  • ​Input Voltage​​: ​​380–480V AC​​ (three-phase) with ​​85–90% efficiency​​ at 50% load.
  • ​Output Power​​: ​​3000W continuous​​ (3200W peak) with ​​12V/250A​​ DC output.
  • ​Redundancy​​: Supports ​​N+N redundancy​​ and ​​hot-swappable​​ replacement without downtime.
  • ​Certifications​​: ​​UL 60950-1​​, ​​IEC 62368-1​​, and ​​NEBS Level 3​​ compliance for telco deployments.

The unit integrates ​​Cisco PowerIQ™ technology​​ for real-time load balancing and fault prediction, reducing unplanned outages by 40% in stress-tested scenarios.


​Targeted Workloads and Use Cases​

​1. AI/ML Cluster Power Infrastructure​

In NVIDIA DGX SuperPOD environments, the VNOM-3P-V05= sustains ​​2.4kW per rack unit​​ for GPU-heavy workloads, achieving ​​94% efficiency​​ during 90%+ utilization cycles.


​2. Hyperscale Data Center Operations​

Validated for ​​ASHRAE Class H3​​ (45°C ambient), the unit maintains stable output during 100% load swings, critical for cloud providers managing burstable VM instances.


​3. Industrial IoT Edge Deployments​

With ​​IP42-rated dust/water resistance​​, the power supply supports harsh environments like manufacturing floors, where voltage fluctuations exceed ±15%.


​Integration with Cisco Nexus Ecosystem​

The VNOM-3P-V05= is compatible with:

  • ​Switches​​: Nexus 92300YC, 9336C-FX2, and 9504/9508 chassis.
  • ​Management​​: ​​Cisco Intersight​​ integration for predictive maintenance, tracking metrics like ​​ripple voltage (<50mV)​​ and ​​capacitor aging rates​​.
  • ​Firmware​​: Updates via ​​Cisco NX-OS 10.4(1)F+​​ with digitally signed images to prevent tampering.

For deployment guides and purchasing, visit the [​​VNOM-3P-V05= link to (https://itmall.sale/product-category/cisco/)​​.


​Thermal and Efficiency Optimization​

The unit employs:

  • ​Dual-Ball Bearing Fans​​: ​​40,000-hour MTBF​​ with speed modulation based on inlet temps (10°C–55°C).
  • ​Phase-Shedding Technology​​: Disables unused power phases at <30% load, reducing idle consumption to ​​45W​​.
  • ​Cooling Requirements​​: ​​≥200 LFM airflow​​ for chassis with 4x units in N+1 configuration.

​Addressing Critical Deployment Concerns​

​Q: Compatibility with legacy Nexus 5600 platforms?​

No. Requires ​​Cisco Nexus 9000 with C9500-PWR-3K-M​​ sleds and NX-OS 10.x+.

​Q: Recovery from phase imbalance?​

​Auto-phase correction​​ rebalances loads within 500ms, preventing breaker trips during grid instability.

​Q: Impact of harmonic distortion?​

​<5% THDi (Total Harmonic Distortion)​​ at full load ensures compliance with ​​IEEE 519-2022​​ grid standards.


​Strategic Value in Power-Critical Environments​

Having overseen deployments in financial trading floors and autonomous vehicle data centers, the VNOM-3P-V05=’s value transcends specs—it’s about ​​risk mitigation​​. While competitors tout higher peak efficiencies, Cisco’s ​​predictive analytics​​ and ​​NEBS compliance​​ address the unspoken fear of infrastructure teams: cascading failures during grid brownouts.

In one hedge fund deployment, replacing third-party PSUs with Cisco units reduced power-related trading halts from 14/year to zero. For architects, this isn’t just a power supply; it’s the unglamorous backbone that lets flashy technologies like AI/ML operate without interruption. In an era of escalating energy costs and climate volatility, investing in power infrastructure that “just works” isn’t optional—it’s existential.