Cisco UCSXSD32TKA3XEP-D=: High-Density 32TB NVMe SSD for Hyperscale Storage and AI Workloads



Product Overview and Target Applications

The ​​Cisco UCSXSD32TKA3XEP-D=​​ is a 32TB NVMe SSD engineered for Cisco’s UCS X-Series modular systems, targeting hyperscale storage, AI/ML training datasets, and archival workloads. Designed as a ​​“Tier 2” storage solution​​, it balances high capacity with moderate endurance, enabling cost-effective petabyte-scale deployments in cloud-native and enterprise environments.


Technical Specifications and Architectural Innovations

Based on Cisco’s documentation and ​itmall.sale​ technical listings, the UCSXSD32TKA3XEP-D= features:

  • ​32TB capacity​​ via ​​PCIe Gen4 x4 NVMe 2.0​​ interface (6,500 MB/s read, 3,900 MB/s write).
  • ​E3.S 2T form factor​​ (14mm height) with ​​QLC (Quad-Level Cell) NAND​​ and ​​dynamic SLC caching​​.
  • ​0.3 DWPD (Drive Writes Per Day)​​ endurance over 5 years (17.5 PBW total).
  • ​TCG Opal 2.0 encryption​​ and ​​power-loss protection (PLP)​​ via supercapacitors.
  • ​-40°C to 70°C operational range​​ for edge and industrial IoT use cases.

The drive employs ​​asymmetric write acceleration​​, dedicating 12% of its NAND to buffer burst writes, mitigating QLC’s inherent write amplification challenges.


Compatibility and Integration Requirements

Supported UCS Platforms

  • ​UCS X9508 Storage Node​​: Validated for ​​24x drives​​ per chassis (768TB raw capacity).
  • ​UCS X210c M7 Compute Node​​: Supports ​​4x drives​​ as a secondary storage tier.

Critical Deployment Notes:

  • ​UCS Manager 5.4(1)​​ or later for NVMe-oF target mode and encryption key management.
  • ​RAID 6 mandatory​​ for arrays >8 drives to offset QLC reliability risks.
  • ​Cisco UCS VIC 15425 adapters​​ required for PCIe Gen4 lane bifurcation.

Performance Benchmarks and Use Cases

Cisco’s internal testing (via restricted reports) highlights:

​Hyperscale Data Lakes​

  • ​95% sequential read stability​​ at 6.2 GB/s under 90% capacity utilization.
  • ​1.2W/TB idle power consumption​​, reducing energy costs by 50% vs. HDD-based archives.

​AI/ML Training​

  • ​4.1x faster dataset ingestion​​ for ResNet-101 vs. SATA QLC SSDs.
  • ​22 ms latency​​ for Parquet file access in distributed TensorFlow clusters.

​Cold Archival​

  • ​10-year data retention​​ with ​​<0.8% annual bit error rate (BER)​​ at 30°C ambient.

Deployment Best Practices

Configuration and Optimization

  • ​Overprovisioning​​: Reserve ​​15% capacity​​ via nvme format to sustain write performance.
  • ​Thermal Management​​: Maintain ​​180 LFM airflow​​ to keep drive temps < 55°C during sustained operations.
  • ​Firmware Updates​​: Apply ​​UCSXSD32TKA3XEP-1.4.0d​​ to address QLC read-retry latency spikes.

RAID and Security

  • ​RAID 60​​: Recommended for multi-petabyte arrays to limit rebuild times to <72 hours.
  • ​Key Management​​: Integrate with Cisco Intersight’s ​​Hybrid Cloud Key Manager​​ for geo-redundant encryption.

Addressing Key User Concerns

Endurance and Reliability

At ​​0.3 DWPD​​, the drive supports ​​~5.7 TB/day​​ of writes—sufficient for weekly backups or incremental AI/ML logs. For mixed workloads:

  • ​Write Throttling​​: Enable ​​NVMe Write Protect Mode​​ during peak hours.
  • ​Health Monitoring​​: Track ​​Media Wear Percentage​​ via Cisco UCS Manager’s dashboard.

Total Cost of Ownership (TCO)

Priced at ​12,500–12,500–12,500–13,800 per drive​​, the UCSXSD32TKA3XEP-D= offers ​​$0.39/GB​​—60% lower than Cisco’s 15TB TLC drives. Trade-offs include:

  • ​Extended rebuild times​​ (32TB rebuilds take ~40 hours in RAID 6).
  • ​Limited random write performance​​ (4,200 IOPS vs. 90,000+ on TLC NVMe).

Vendor Lock-In and Repurposing

Only ​UCSXSD32TKA3XEP-D= drives purchased via itmall.sale​ include ​​5-year firmware support​​ and PLP validation. Third-party drives risk incompatibility with Cisco’s RAID controllers and NVMe-oF stacks.


Strategic Insights for Storage Architects

The UCSXSD32TKA3XEP-D= is a double-edged sword—its 32TB capacity reshapes storage economics but locks enterprises into Cisco’s ecosystem. For hyperscalers and media giants drowning in unstructured data, it’s a lifeline. For performance-centric workloads, it’s a compromise.

Cisco’s focus on ​​QLC + SLC caching​​ acknowledges the reality of modern data hoarding, but the lack of SMR support limits its appeal for tape replacement use cases. The drive’s ​​-40°C tolerance​​ unlocks deployments in extreme environments like Arctic research stations, yet its absence of CXL 2.0 compatibility sidelines it from memory-tiering innovations.

One underrated strength is its ​​TCG Opal integration with Intersight​​, which simplifies compliance for global enterprises. However, the lack of FIPS 140-3 certification narrows its utility in regulated sectors like healthcare or defense.

In an era where data gravity dictates infrastructure design, this drive is a pragmatic choice for enterprises prioritizing capacity over agility. It won’t win benchmarks, but in the unglamorous trenches of petabyte-scale storage, it’s a workhorse that gets the job done—provided you’re willing to play by Cisco’s rules.

For those entrenched in UCS ecosystems, the UCSXSD32TKA3XEP-D= is a logical step toward sustainable scalability. For others, it’s a reminder that in storage, every terabyte saved comes with a terabyte of vendor commitment.

Related Post

Cisco NCS4009-SA-AC=: High-Efficiency AC Powe

​​Hardware Overview and Functional Role​​ The �...