Hardware Specifications and Core Design
The Cisco UCSX-SDB3T8SA1V= is a 2.5-inch NVMe Gen4 enterprise SSD engineered for Cisco’s UCS X-Series, delivering 3.8TB of raw capacity with 7.2 GB/s sequential read and 4.8 GB/s write speeds. Built on 176-layer 3D TLC NAND technology, the drive achieves 1.3 DWPD endurance over a 5-year lifespan, targeting mixed enterprise workloads like OLTP databases and virtualization.
Key innovations include:
- Cisco Secure Boot Guard: Hardware-rooted firmware validation compliant with FIPS 140-3 Level 2
- Dual-Port PCIe 4.0 x4 Interface: Supports active-active failover with 18μs path switch latency
- Dynamic Overprovisioning: Adjusts OP from 7% to 28% via Cisco UCS Manager 5.4(1a)+
Compatibility and Firmware Requirements
Validated for deployment in:
- Cisco UCS X210c M7 Compute Nodes: Requires BIOS X210CM7.4.1.3e and CIMC 6.4(2a)
- Hypervisors: VMware vSphere 8.0 U3 (vVols 4.0) and Red Hat OpenShift 4.12 (CSI 3.6+)
- RAID Configurations: RAID 0/1/10 via Cisco UCS 9460-8i Gen4 controller
Critical compatibility notes:
- Mixing with SAS SSDs in the same storage pool reduces performance by 24% due to protocol overhead
- UCSX 9508 Chassis Manager 4.3+ required for thermal coordination in dense configurations
- Incompatible with UCS C240 M5 servers lacking PCIe bifurcation support
Performance Benchmarks
Cisco TAC validation results (24-drive cluster):
- Random 4K Read: 1.5M IOPS at 150μs latency (QD256)
- Mixed Workload: 620K IOPS (70/30 R/W) with 1.1ms P99 latency
- Sequential Write: Sustained 4.3 GB/s (128K blocks) for 48 hours
Stress testing demonstrated 98.5% of drives exceeded 5.1 PBW endurance under 40°C ambient conditions.
Thermal and Power Management
With 18W average power (25W peak):
- Cooling Requirements: 25 CFM front-to-back airflow (ΔT <12°C across drive)
- Throttling Behavior: Reduces PCIe lanes to x2 mode at 75°C NAND junction temp
- Power Capping: Cisco Intersight’s Storage Power Profiler limits drives to 14W during peak demand
Field data shows improper drive spacing increases temps by 11°C, causing 17% performance degradation.
Procurement and Authenticity Verification
For guaranteed performance, [“UCSX-SDB3T8SA1V=” link to (https://itmall.sale/product-category/cisco/) provides:
- Cisco Secure Erase Certificates compliant with NIST 800-88r1
- Pre-loaded firmware with TAA-compliant configurations
- Serialized inventory tracking for audit trails
Gray-market drives often lack Cisco’s Secure Boot Microcode, increasing vulnerability to firmware exploits.
Deployment Scenarios and Constraints
Virtualized Environments:
- Supports 128 NVMe namespaces with per-VM QoS policies
- Validated for VMware vSAN ESA 8.0 deployments
AI Inference Workloads:
- Delivers 1.2M IOPS for TensorFlow Serving with 2ms P99 latency
- Requires 20% OP allocation for optimal checkpointing
Limitations:
- 4K random write performance drops 38% post SLC cache exhaustion
- No hardware encryption for Oracle ASM deployments
- Maximum 32 drives per UCS domain without latency spikes
Technical Perspective
The UCSX-SDB3T8SA1V= strikes a balance between performance and reliability but exposes Cisco’s ecosystem dependencies. While its dual-port architecture ensures high availability, the lack of hardware compression limits cost efficiency for hyperscale storage. For enterprises standardized on UCS X-Series, it remains the optimal Gen4 NVMe solution—particularly in regulated sectors where FIPS compliance justifies the 22% cost premium. However, the drive’s inability to leverage PCIe 5.0 in next-gen M8 nodes may shorten its relevance as AI datasets grow exponentially. Its long-term viability hinges on Cisco’s commitment to backward compatibility in future chassis iterations.