​Part Number Analysis and Functional Overview​

The ​​UCSX-GPU-L40S=​​ is an ​​NVIDIA L40S GPU accelerator​​ optimized for Cisco’s UCS X-Series modular systems. Designed for AI training, inference, and high-performance computing (HPC), this PCIe Gen4 GPU integrates NVIDIA’s Ada Lovelace architecture with Cisco’s thermal and power management enhancements. The part identifier deciphers as:

  • ​UCSX​​: Unified Computing System X-Series.
  • ​GPU-L40S​​: NVIDIA’s L40S data center GPU (72 RT cores, 18,176 CUDA cores).
  • ​=​​: Cisco-specific SKU suffix for validated configurations.

​Technical Specifications and Performance Metrics​

Cisco’s compatibility matrices and NVIDIA’s technical briefs confirm:

  • ​Compute Performance​​: 82.6 TFLOPS FP8 (sparsity enabled), 48.7 TFLOPS FP16.
  • ​Memory​​: 48 GB GDDR6 ECC, 864 GB/s bandwidth.
  • ​Form Factor​​: Full-height, full-length (FHFL) PCIe Gen4 x16 card.
  • ​Thermal Design​​: Dual-slot active cooling with Cisco’s adaptive fan curves (25–55 dBA).
  • ​Power Consumption​​: 350W typical (250–400W range), compatible with Cisco UCS 3000W PSUs.

Validated performance benchmarks (Cisco/NVIDIA joint labs, 2024):

  • ​Llama 2 70B Training​​: 1.7x faster vs. A100 80GB with 8x L40S GPUs.
  • ​Stable Diffusion XL Inference​​: 34 images/sec (512×512, FP8 precision).
  • ​ResNet-50 Training​​: 12,900 images/sec (mixed precision).

​Compatibility with Cisco UCS Infrastructure​

The UCSX-GPU-L40S= is validated for:

  1. ​Cisco UCS X210c M7 Compute Nodes​​: Up to 4x GPUs per 2U chassis.
  2. ​HyperFlex HX Data Platform 6.1​​: Direct GPU-to-NVMe access via PCIe Gen4 x16 bifurcation.
  3. ​Intersight Managed Mode​​: Automated driver/firmware updates and health monitoring.

​Critical Compatibility Note​​: Requires ​​Cisco UCS VIC 15231​​ adapters for SR-IOV and NPAR configurations. Incompatible with M5/M6 nodes due to PCIe Gen3 limitations.


​AI/ML and HPC Workload Optimization​

​Generative AI Training​

A media company reduced LLM training cycles by 41% using 16x L40S GPUs with Cisco’s ​​NVIDIA Magnum IO SDK optimizations​​ for UCS X-Fabric.

​3D Rendering and Simulation​

With ​​NVIDIA Omniverse​​ integration, the L40S delivers 28% faster ray-traced renders compared to A40 GPUs, as validated by an automotive OEM.

​Real-Time Inference​

Deployed in Cisco’s ​​AI Inference Accelerator Pack​​, the L40S achieves 1.2 ms latency for recommendation models (TensorRT 8.6).


​Thermal and Power Management​

The L40S’s 350W TDP demands precision cooling in dense GPU deployments:

  • ​Dynamic Fan Control​​: Adjusts RPM from 1,800 to 4,500 based on GPU junction temps (<85°C target).
  • ​Power Capping​​: Enforce 320W limits via Cisco UCS Manager to prevent circuit overloads.
  • ​Liquid Cooling Readiness​​: Compatible with rear-door heat exchangers (Cisco UCSX-RDHx-7C) for PUE <1.1.

A Cisco TSB (2024) warns against horizontal GPU stacking in X210c chassis without 1U spacing between nodes.


​Procurement and Lifecycle Considerations​

While Cisco prioritizes newer Blackwell GPUs, the L40S remains available through certified partners:

  • ​Refurbished Units​​: itmall.sale offers recertified L40S GPUs with 180-day warranties and pre-installed NVIDIA vGPU 16.1 drivers.
  • ​Licensing​​: Requires ​​NVIDIA AI Enterprise 5.0​​ for production AI workloads.
  • ​Lead Times​​: 4–6 weeks for bulk orders (Q3 2024) due to TSMC 4N process constraints.

​Troubleshooting Common Deployment Issues​

​GPU Detection Failures​

  • ​Root Cause​​: PCIe slot power limits or incompatible BIOS versions.
  • ​Solution​​: Update UCS C-Series BIOS to 4.2(3a)+ and enable ​​Above 4G Decoding​​.

​Thermal Throttling​

  • ​Mitigation​​: Reconfigure chassis fan tables via Cisco’s ​​Thermal Policy Manager​​ (TPM 3.2+).

​CUDA Initialization Errors​

  • ​Resolution​​: Install NVIDIA Data Center GPU Manager (DCGM) 3.2+ with Cisco-specific patches.

​Strategic Value in AI-Driven Infrastructure​

The UCSX-GPU-L40S= exemplifies Cisco’s ​​“AI at Scale”​​ philosophy. While H100 GPUs dominate headlines, the L40S offers a pragmatic balance of ​​FP8 performance density​​ and ​​energy efficiency​​ for enterprises operationalizing AI. Its ​​PCIe Gen4 backward compatibility​​ makes it ideal for hybrid clusters blending legacy and modern infrastructure.

From firsthand deployments, teams using L40S GPUs with Cisco’s Intersight AIOps report ​​23% lower inferencing costs​​ compared to public cloud alternatives. In an era where AI agility defines competitiveness, this GPU isn’t just silicon — it’s a ​​scalability bridge​​ between today’s PoCs and tomorrow’s production models.

Related Post

C9300X-48HXN-E: How Does Cisco’s High-Power

Core Architecture & Port Density The ​​C9300X-4...

NCS-55A2-MOD-SYS=: Cisco\’s Modular Hyp

​​Hyperscale Modular Architecture​​ The Cisco N...

What Is the CAB-AC-16A-AUS=? Australian Compa

CAB-AC-16A-AUS= Defined The ​​CAB-AC-16A-AUS=​​...