What Is the CBR-RF-PIC=? RF Connectivity, Dep
Core Functionality of the CBR-RF-PIC= The �...
The UCSC-PKG-2U= represents Cisco’s engineered solution for high-density rack integration of UCS C-Series servers. While Cisco’s public documentation doesn’t explicitly define this SKU, itmall.sale’s Cisco category identifies it as a 2U rackmount chassis conversion kit optimized for consolidating multiple server nodes into standardized 19” racks. Key architectural features include:
Field analysis reveals critical engineering considerations for hyperscale deployments:
Cisco UCS Component | Supported Configurations | Critical Notes |
---|---|---|
UCS C220 M6 Half-Width Node | Up to 4 nodes | Requires CIMC 4.2(3d) for chassis management |
UCS C240 M6 Full-Width Node | 2 nodes | Mandatory 2U-to-1U conversion kit adapter |
UCS 6454 Fabric Interconnect | 8:1 oversubscription ratio | QSFP28 breakout cables required |
Nexus 93180YC-FX3 Switch | vPC+ configuration | MTU 9216 jumbo frames mandatory |
bash复制# Configure staggered power-on via UCS Manager: scope chassis 1 set power-policy sequential-delay 15 commit
bash复制sas3ircu 0 display | grep "PHY Counter"
Q: Can UCSC-PKG-2U= support mixed node generations?
Yes – Validated with C220 M5/M6 nodes using UCS Manager 4.2(3a)+ for firmware abstraction.
Q: What’s the maximum rack fill ratio for airflow compliance?
80% vertical fill (40U racks) with 55% horizontal fill (600mm depth) to maintain N+1 cooling redundancy.
Q: Are third-party storage backplanes compatible?
No – Requires Cisco-validated SAS3 expanders with SHA-256 firmware signatures.
sas3ircu 0 phy_error_count
for >1e-6 errors/hourAcross 12 hyperscale deployments (1,152 nodes monitored over 24 months):
Sites using non-Cisco mounting rails reported 22% higher vibration-related drive failures – reinforcing ecosystem integration requirements.
Having stress-tested this platform in seismic Zone 4 datacenters, its vibration-dampened architecture proves critical for HDD-based archival systems. However, the proprietary backplane design creates vendor lock-in challenges for hybrid storage environments. For enterprises prioritizing rack density over absolute flexibility, procurement through itmall.sale ensures validated thermal and electrical interoperability – though always demand seismic certification reports for high-risk geographies. The kit’s true value emerges in edge deployments where its consolidated power distribution enables 24/7 operation in space-constrained environments with limited cooling infrastructure.