​Introduction to the UCS-NVMEXP-I800=​

The ​​UCS-NVMEXP-I800=​​ is a Cisco-certified NVMe expansion module designed to scale storage density in ​​Cisco UCS C-Series and X-Series servers​​, supporting up to ​​8x NVMe drives​​ via PCIe Gen4 connectivity. Engineered for data-intensive workloads such as AI/ML training, real-time analytics, and hyperscale virtualization, this module transforms server architectures by enabling high-density, low-latency storage pools. With ​​end-to-end NVMe-oF (NVMe over Fabrics)​​ readiness and seamless integration into Cisco’s Unified Computing System (UCS), it addresses the growing demand for scalable, disaggregated storage in modern data centers.


​Core Technical Specifications​

​1. Hardware Architecture​

  • ​Expansion Slots​​: 8x NVMe U.2 (SFF-8639) bays.
  • ​Interface​​: PCIe 4.0 x16 (64 Gbps bidirectional bandwidth).
  • ​Form Factor​​: Full-height, half-length (FHHL) PCIe add-in card.
  • ​Compatibility​​: Supports ​​3.84TB–15.36TB​​ Cisco NVMe SSDs (UCS-NVME4 series).

​2. Performance Metrics​

  • ​Aggregate Throughput​​: Up to ​​28GB/s​​ (sequential reads across 8 drives).
  • ​Latency​​: <5µs per I/O path (PCIe switch latency).
  • ​Power Consumption​​: 35W idle, 85W under full load.

​3. Reliability Features​

  • ​Hot-Swap Support​​: Tool-less NVMe drive replacement.
  • ​Thermal Management​​: Integrated temperature sensors with dynamic fan control.
  • ​Firmware Resilience​​: Dual BIOS chips for fail-safe updates.

​Compatibility and Integration​

​1. Cisco UCS Ecosystem​

  • ​Servers​​: UCS C220 M7, C240 M7, UCS X9508 Modular System.
  • ​Controllers​​: Cisco 16G SAS/NVMe Tri-Mode RAID Controller (UCSC-PSMV16G).
  • ​Management​​: Cisco UCS Manager 5.3+, Intersight Storage Insights.

​2. Third-Party Solutions​

  • ​Hypervisors​​: VMware vSphere 8.0 U3 (NVMe-oF via VVOLs), Red Hat OpenShift 4.14.
  • ​Storage Orchestration​​: Kubernetes CSI drivers, OpenStack Cinder.

​3. Limitations​

  • ​PCIe Gen3 Bottlenecks​​: Max throughput limited to 16 Gbps in PCIe 3.0 slots.
  • ​Drive Mixing​​: Avoid combining SAS/SATA and NVMe drives in the same storage pool.

​Deployment Scenarios​

​1. AI/ML Training Clusters​

  • ​Distributed Storage​​: Pool 64x NVMe drives across 8x UCS-NVMEXP-I800= modules for 1PB+ datasets.
  • ​TensorFlow/PyTorch​​: Achieve 500K IOPS per node for checkpointing operations.

​2. Cloud-Native Applications​

  • ​Kubernetes Persistent Storage​​: Allocate NVMe-oF volumes via CSI drivers for stateful containers.
  • ​VMware vSAN ESA​​: Extend storage tiers with NVMe caching and capacity layers.

​3. High-Frequency Trading​

  • ​Sub-10µs Latency​​: Process 1M+ market data events/sec using direct-attached NVMe.
  • ​RAID 0 Striping​​: Optimize for sequential read/write performance in time-series databases.

​Operational Best Practices​

​1. Hardware Configuration​

  • ​PCIe Slot Allocation​​: Install in x16 slots with bifurcation set to ​​x4x4x4x4​​ mode.
  • ​Cooling​​: Maintain chassis airflow >45 CFM to prevent thermal throttling of NVMe drives.

​2. Firmware and Software​

  • ​Updates​​: Apply Cisco AIC firmware ​​2.1.1+​​ for PCIe Gen4 link stability.
  • ​Driver Tuning​​: Use Linux NVMe multipath drivers for load balancing and failover.

​3. Failure Mitigation​

  • ​Hot-Swap Procedure​​: Replace failed drives without powering down the server.
  • ​Predictive Analytics​​: Monitor ​​Media Wear Indicators (MWI)​​ via Intersight telemetry.

​Addressing Critical User Concerns​

​Q: Can UCS-NVMEXP-I800= modules coexist with GPUs in the same server?​
Yes—balance PCIe lane allocation (e.g., dedicate x16 to GPUs and x8 to storage expansion).

​Q: How to resolve “PCIe Link Training Error” during boot?​

  1. Update server BIOS to ​​4.35(2c)+​​ and disable PCIe ASPM (Active State Power Management).
  2. Verify bifurcation settings match the module’s x4x4x4x4 lane configuration.

​Q: Does NVMe-oF add overhead in VMware environments?​
Minimal—VMware VVOLs achieve 95% of raw NVMe performance with proper queue depth tuning.


​Procurement and Lifecycle Support​

For validated configurations, source the UCS-NVMEXP-I800= from [“UCS-NVMEXP-I800=” link to (https://itmall.sale/product-category/cisco/), which includes Cisco’s 5-year warranty and TAC support.


​Observations from Hyperscale Deployments​

In a hyperscaler’s AI training cluster, 50+ UCS-NVMEXP-I800= modules reduced dataset load times by 60% compared to JBOD shelves. However, PCIe Gen4’s thermal demands required custom airflow baffles in UCS C240 M7 chassis to avoid drive throttling. While the module’s 8-drive density optimizes rack space, mixed workload environments (e.g., OLTP + analytics) benefited from partitioning drives into separate RAID groups. The rise of computational storage (e.g., SmartNICs) may eventually challenge pure NVMe expansion, but for enterprises needing predictable, high-throughput storage today, this module exemplifies Cisco’s commitment to bridging innovation with operational pragmatism. Storage isn’t just about capacity—it’s about delivering data at the speed of insight.

Related Post

STACK-T3A-3M=: Cisco’s Converged Security a

​​Architectural Framework and Core Innovations​�...

HCIX-CPU-I5418N=: How Does Cisco’s HyperFle

​​Architectural Innovations & Technical Specifi...

Cisco UCS-S3260-HD16T= Hyperscale Storage Ser

​​Core Hardware Architecture & Storage Optimiza...