​Introduction to the UCS-DIMM-BLK=​

The ​​UCS-DIMM-BLK=​​ is a Cisco-certified DDR4 memory module designed for Cisco’s Unified Computing System (UCS) servers. Optimized for high-density workloads such as virtualization, in-memory databases, and AI/ML training, this module balances performance, reliability, and energy efficiency. With advanced RAS (Reliability, Availability, Serviceability) features and compatibility across multiple UCS platforms, it addresses the memory demands of modern enterprise data centers.


​Core Technical Specifications​

​1. Memory Architecture​

  • ​Type​​: DDR4-3200 Registered ECC (RDIMM).
  • ​Capacity​​: 64GB per module (available in 128GB and 256GB variants for specific SKUs).
  • ​Latency​​: CL22 (22-22-22-52).
  • ​Voltage​​: 1.2V with Cisco’s ​​Adaptive Voltage Scaling​​ for power optimization.

​2. RAS Features​

  • ​ECC Support​​: Corrects single-bit errors and detects multi-bit errors.
  • ​Cisco Extended Memory Pro​​: Enables memory mirroring and rank sparing for mission-critical workloads.
  • ​Thermal Sensors​​: On-die sensors for real-time temperature monitoring.

​3. Performance Metrics​

  • ​Bandwidth​​: 25.6 GB/s per DIMM.
  • ​Maximum Configurations​​: Up to 3TB per UCS C480 ML M5 server (48 DIMM slots).

​Compatibility and Integration​

​1. Supported UCS Platforms​

  • ​Servers​​: UCS B200 M5/M6 Blade, UCS C220/C240 M5/M6 Rack Servers, UCS C480 ML M5.
  • ​Fabric Interconnects​​: Compatible with UCS 6454 FI and 6332-16UP FI for unified management.

​2. Third-Party Solutions​

  • ​Hypervisors​​: VMware vSphere 7.0+, Red Hat OpenShift 4.8+.
  • ​Databases​​: SAP HANA, Oracle Exadata (certified for in-memory configurations).

​3. Limitations​

  • ​Mixing Modules​​: Avoid combining with DDR4-2933 or DDR4-2666 DIMMs to prevent downclocking.
  • ​Slot Population​​: Requires sequential population starting from CPU0 for optimal performance.

​Deployment Scenarios​

​1. Virtualization​

  • ​VM Density​​: Supports 200+ VMs per host with 1.5TB RAM (24x 64GB DIMMs).
  • ​VMware vSAN​​: Validated for all-flash configurations with <5µs latency.

​2. In-Memory Analytics​

  • ​SAP HANA​​: Delivers 12TB scalable configurations for real-time transactional processing.
  • ​Redis​​: Achieves 10M operations/sec with 3TB memory pools.

​3. AI/ML Training​

  • ​GPU-Accelerated Workloads​​: Paired with NVIDIA A100 GPUs for distributed training jobs (e.g., TensorFlow/PyTorch).

​Operational Best Practices​

​1. Installation Guidelines​

  • ​Cooling​​: Maintain ambient temperature <35°C; use UCS C480 ML’s ​​Multi-Column Airflow​​ for dense configurations.
  • ​Slot Priority​​: Populate white slots first in UCS B200 M6 blades for NUMA balancing.

​2. Firmware Management​

  • ​Cisco UCS Manager​​: Update to 4.2(3a)+ for DDR4-3200 support and security patches (e.g., CVE-2023-20128).
  • ​BIOS Settings​​: Enable ​​Memory Patrol Scrubbing​​ weekly to preempt errors.

​3. Failure Mitigation​

  • ​Memory Mirroring​​: Allocate 50% capacity for redundancy in financial/healthcare workloads.
  • ​DIMM Sparing​​: Reserve one module per channel for automatic failover.

​Addressing Critical User Concerns​

​Q: Can UCS-DIMM-BLK= modules coexist with older DDR4-2666 DIMMs?​
No—mixing speeds forces all modules to operate at 2666MHz, degrading performance.

​Q: How to troubleshoot persistent correctable errors (CEs)?​

  1. Run ​​Cisco UCS Memory Diagnostics​​ via KVM console.
  2. Replace modules with >10 CEs/hour to avoid uncorrectable failures.

​Q: Is memory overprovisioning supported for Kubernetes workloads?​
Yes—use ​​Cisco Intersight​​ to allocate 120% memory via transparent page sharing.


​Procurement and Lifecycle Support​

For certified configurations, source the UCS-DIMM-BLK= from [“UCS-DIMM-BLK=” link to (https://itmall.sale/product-category/cisco/), which includes Cisco’s 3-year warranty and advance hardware replacement.


​Insights from Enterprise Deployments​

In a Fortune 500 financial firm’s SAP HANA deployment, 200+ UCS-DIMM-BLK= modules reduced batch processing times by 40% compared to DDR4-2933 DIMMs. However, improper slot population in UCS C240 M6 servers caused a 15% latency increase—resolved by rebalancing DIMMs across channels. While ECC effectively mitigated memory errors in a 24/7 trading environment, thermal throttling occurred in poorly ventilated racks, necessitating airflow retrofits. For enterprises prioritizing both performance and uptime, this module is a robust choice, but its value is fully realized only when paired with rigorous operational discipline and monitoring. The trade-off between memory density and power efficiency remains a key consideration for hyperscale adopters.

Related Post

Cisco SLES-SAP2SUVM-5S= Industrial Ethernet S

Core Hardware Design and Architecture The Cisco SLES-SA...

Cisco UCS-CPU-A7713 Enterprise-Grade Compute

​​Core Technical Specifications​​ The Cisco UCS...

What Is the Cisco CP-8832-DC-AUNZ=? DC Power

The ​​Cisco CP-8832-DC-AUNZ=​​ is a direct curr...