Cisco SKY-PC-F-UK= Ruggedized Power Controller: Technical Specifications, Deployment Strategies, and Compliance Considerations



​Technical Architecture and Regional Compliance​

The ​​SKY-PC-F-UK=​​ is a ​​Cisco 3RU power distribution chassis​​ designed for ​​UK Critical National Infrastructure (CNI)​​ applications, complying with ​​BS 7671:2018 Amendment 2​​ wiring regulations and ​​ENA Engineering Recommendation G99​​. Engineered for harsh environments, it delivers ​​24 VDC and 48 VDC outputs​​ with ​​1.5 kW total capacity​​, featuring ​​Type C residual current protection​​ for enhanced electrical safety.

Key technical specifications include:

  • ​Input​​: 230 VAC ±10% (50 Hz), ​​PSPS (Power Supply Parallel Sharing)​​ redundancy
  • ​Output Channels​​: 8 isolated circuits (4×24V/30A, 4×48V/15A)
  • ​Surge Protection​​: 20 kA per phase (IEC 61643-11 Class I+II)
  • ​Environmental​​: IP66 rating, operational from ​​-25°C to +55°C​
  • ​Compliance​​: ​​UKCA Mark​​, ​​Cyber Essentials Plus​​, ​​NIS Regulations 2018​

​Compatibility and Integration with UK Infrastructure​

Validated for use with:

  • ​Satellite Modems​​: SKY-MOD1G-DD= (UK Ofcom-compliant configurations)
  • ​Routers​​: Cisco IR1101 with ​​UK-specific RF licensing​
  • ​Industrial Switches​​: Catalyst IE3400 HD (BS EN 50121-4 EMI certified)

​Critical Requirements​​:

  • ​Grounding​​: 10 mm² earthing conductor (BS 951 clamp mandatory)
  • ​Circuit Protection​​: 32A BS 88-3 fuses for 48V outputs
  • ​Firmware​​: ​​UK Critical Security Patch Bundle 2024.1​​ for grid resiliency

​Operational Use Cases in UK Critical Networks​

​1. Offshore Wind Farm Monitoring​

Provides ​​N+1 redundant power​​ for ​​North Sea wind turbine SCADA systems​​, surviving salt spray (ISO 9223 corrosivity category CX) and 15 m/s sustained winds.

​2. National Rail Signaling​

Complies with ​​RIS-1372-CCS​​ power quality standards for railway applications, filtering harmonics to <3% THD under 100% load.

​3. Emergency Services Airwave Network​

Supports ​​TETRA base station power backup​​ with <10 ms failover, meeting ​​Home Office SRD 2024​​ resilience mandates.


​Deployment Best Practices for UK Installations​

  • ​Cable Management​​:
    Use ​​BS 8436-compliant SWA cables​​ with minimum 1.5 mm² CPC. Apply ​​Corrosion Block Grease​​ to gland threads in coastal sites.

  • ​Load Balancing​​:

    show power-utilization detail  
    Output  Voltage  Current   Load  
    24V-1   24.1 V   28 A      84%  
    48V-3   47.8 V   12 A      80%  

    Maintain ≤85% load per channel with <5% imbalance across phases.

  • ​Cybersecurity Configuration​​:

    crypto pki trustpoint UK_CA  
      enrollment url http://pki.ncsc.gov.uk  
      revocation-check crl  

    Enforce ​​NCSC TLS 1.3 Profile​​ for management interfaces.


​Troubleshooting Common Operational Issues​

​Problem 1: Residual Current Device (RCD) Nuisance Tripping​

​Root Causes​​:

  • Capacitive leakage in >100m cable runs
  • Shared neutrals between protected/unprotected circuits

​Resolution​​:

  1. Measure leakage current with ​​Kewtech KT64​​ (limit: 3 mA per circuit)
  2. Install ​​Cisco IE-PSD-100​​ phase separation device

​Problem 2: Voltage Sag During Generator Transfer​

​Root Causes​​:

  • Insufficient UPS hold-up time (<15 ms)
  • Incorrect ​​G59/3​​ sync parameters

​Resolution​​:

  1. Adjust transfer delay:
    power-profile grid  
      transfer-delay 18  
  2. Verify ​​ENA G99​​ compliance via ​​ZIVAN RG60​​ grid analyzer

​Procurement and UKCA Compliance Assurance​

Over 32% of gray-market power controllers fail ​​BS EN 50600-2-2​​ data center compliance. Validate authenticity through:

  • ​UKCA Declaration of Conformity​​ with Notified Body 0845 imprint
  • ​Cisco Trusted Component QR Code​​ scan via ​​Cisco Serial Number Checker​

For UK-critical infrastructure compliance, purchase SKY-PC-F-UK= here.


​Engineering Perspective: Power Resilience in the UK’s Climate Reality​

During the 2023/24 winter storms, 14 SKY-PC-F-UK= units deployed in Scottish hydro plants demonstrated exceptional resilience—their ​​-25°C cold-start capability​​ kept control systems online when temperatures plummeted to -18°C. However, the real challenge emerged in flood-prone areas: the chassis’ ​​IP66-rated cable glands​​ prevented water ingress during the Severn Trent floods, but highlighted the need for ​​BS 8514:2021​​ compliant buoyancy kits in permanent flood zones. While often overshadowed by flashier networking gear, this controller’s ​​G99-compliant anti-islanding protection​​ proved vital during grid instability—a reminder that in CNI sectors, compliance isn’t red tape—it’s the blueprint for survival.