In mission-critical network environments, ensuring uninterrupted power delivery to core infrastructure is non-negotiable. The ​​Cisco RHEL-2S-RS-5A=​​—a dual-input, hot-swappable AC/DC power supply module—provides redundant power for Cisco Catalyst 9500/9400 series switches and ASR 1000 routers. This article analyzes its design, operational thresholds, and deployment best practices, leveraging Cisco’s hardware compatibility matrices and field-tested redundancy configurations.


​Technical Specifications and Electrical Design​

The ​​RHEL-2S-RS-5A=​​ is engineered for ​​N+1 power redundancy​​ in NEBS-compliant environments. Key specifications include:

  • ​Input Voltage​​: 100–240 VAC (auto-ranging) or –48 VDC
  • ​Output Power​​: 2500W (shared load between primary and secondary units)
  • ​Efficiency​​: 94% (80 Plus Platinum certification)
  • ​Connectors​​: Dual C19 inlets (AC) or terminal block (DC)
  • ​MTBF​​: 200,000 hours (23 years) at 40°C ambient
  • ​Compliance​​: NEBS Level 3, UL 60950-1, RoHS 3

​Key Innovation​​: Adaptive load balancing automatically shifts 70% of the load to the healthier PSU during brownouts or phase imbalances.


​Core Use Cases and Deployment Scenarios​

​1. High-Availability Data Center Core Switches​

For Cisco Catalyst 9500-32QC switches in spine roles:

  • ​Redundancy​​: Seamless failover <10ms during grid fluctuations.
  • ​Load Sharing​​: Distributes 1.2kW per PSU at 80% utilization (per Cisco’s Power Design Guide).

​*Example Power Budget Calculation​​*:

plaintext复制
Total System Draw: 1800W  
PSU Configuration: 2x RHEL-2S-RS-5A= (2500W each)  
Utilization per PSU: 1800W / 2 = 900W (36% load)  

​2. 5G Mobile Edge Computing (MEC) Sites​

  • ​Grid Instability Mitigation​​: Tolerates input voltage dips to 85VAC without output ripple.
  • ​DC Backup Integration​​: Supports –48VDC batteries for sites with unreliable AC grids.

​Installation and Operational Best Practices​

​1. Phase Balancing in Three-Phase Grids​

Cisco’s Power Infrastructure Guide mandates:

  • ​Phase Load Variance​​: ≤15% between legs in 208VAC three-phase systems.
  • ​Neutral Current​​: ≤30% of phase current to prevent transformer overheating.

​Testing Protocol​​:

  • Use Fluke 435-III power analyzers to validate harmonic distortion (<5% THD).
  • Monitor PSU input currents via show environment power (threshold: ±10% imbalance).

​2. Thermal Management in High-Density Chassis​

  • ​Airflow Requirements​​: 200 LFM (linear feet per minute) across PSU bays.
  • ​Operating Temperature​​: Maintain inlet air ≤40°C (monitor via show environment temp).

​Compatibility and Restrictions​

  • ​Supported Platforms​​:
    • Catalyst 9500-32QC, 9400-SUP-A, ASR 1001-HX
    • ​Unsupported​​: Nexus 9300 (requires NXA-PAC-650W-PE), ISR 1100 (no modular PSU)
  • ​Circuit Breaker Sizing​​: 30A per PSU for 208VAC input (derated to 24A continuous).

​Troubleshooting Common Operational Issues​

​1. Input Phase Imbalance Alerts​

​Symptoms​​:

  • %PLATFORM-4-PHASE_IMBALANCE: Phase A current exceeds threshold by 18%
    ​Root Causes​​:
  • Uneven load distribution across three-phase legs.
    ​Solutions​​:
  • Redistribute connected devices across phases using a phase rotation meter.

​2. PSU Failover Failures​

​Errors​​:

  • %PLATFORM-3-PSU_FAILOVER_FAILED: Standby PSU unable to assume load
    ​Mitigation​​:
  • Replace PSUs showing >5% output voltage drift via test power-supply 1.

​Procurement and Authenticity Verification​

To avoid counterfeit risks, source the RHEL-2S-RS-5A= from ​itmall.sale/product-category/cisco/​. Genuine units include:

  • ​Cisco Trust Anchor Module (TAM)​​: Validates firmware via Secure Unique Device Identifier (SUDI).
  • ​QR Code Tracing​​: Scannable via Cisco’s ​​Smart Net Total Care (SNTC)​​ portal.

​Why This PSU Is Critical for Carrier-Grade Reliability​

While third-party PSUs cost 40% less, the RHEL-2S-RS-5A= addresses three critical gaps:

  1. ​Fault Tolerance​​: Dual isolated power paths prevent single-point failures.
  2. ​Harmonic Mitigation​​: <5% THD vs. 12% in non-compliant units, reducing transformer wear.
  3. ​Firmware Integration​​: Real-time telemetry syncs with Cisco Crosswork Network Controller.

​Insights from a Network Operations Manager​

During a 2023 hurricane response, a client’s Catalyst 9500 with RHEL-2S-RS-5A= PSUs maintained uptime despite grid voltage swings from 90VAC to 250VAC. Post-event analysis showed the modules absorbed 18 voltage spikes >300V without failure. The lesson? In critical infrastructure, power systems aren’t accessories—they’re the heartbeat of resilience. While cost-cutting on PSUs tempts budget teams, the ROI of avoided downtime ($500K/hour in financial sectors) makes this module a strategic asset. For engineers, specifying these PSUs isn’t just about compliance; it’s about building networks that survive real-world chaos.