​Functional Purpose and Design Rationale​

The ​​PWR-C5-BLANK=​​ is a ​​blanking plate​​ designed for Cisco ​​Nexus 9500 Series​​ and ​​UCS C-Series​​ chassis to cover unused power supply slots. This passive component ensures ​​airflow integrity​​, ​​dust mitigation​​, and ​​safety compliance​​ in high-density data center environments. Cisco specifies its use in configurations where redundant power supplies are not deployed, preventing thermal recirculation and maintaining ASHRAE-recommended cooling efficiency.


​Core Technical Specifications​

―――――――――――――――――――――――――――――――――――――――――――

  • ​Mechanical Design​​:

    • ​Material​​: Cold-rolled steel with anti-oxidation coating
    • ​Dimensions​​: 40mm (H) x 200mm (W) x 30mm (D)
    • ​Weight​​: 0.45kg (1lb)
  • ​Compatibility​​:

    • ​Chassis​​: Nexus 9504/9508/9516, UCS C480 ML M5
    • ​Slot Types​​: AC/DC PSU bays for PWR-C5-1KWAC= and equivalents
  • ​Environmental Resilience​​:

    • ​Temperature Range​​: -10°C to 70°C
    • ​Humidity​​: 5–95% non-condensing

―――――――――――――――――――――――――――――――――――――――――――

  • ​Safety Compliance​​:
    UL 94V-0 flammability rating, RoHS 3, and NEBS Level 3.

​Deployment Scenarios and Operational Impact​

―――――――――――――――――――――――――――――――――――――――――――
​Case 1: Hyperscale Data Center Cooling Efficiency​

  • Deployed in ​​Equinix LD8 IBX​​ for Nexus 9508 chassis with 3/4 PSU slots populated:
    • Reduced ​​hotspot temperatures​​ by 8°C via prevention of airflow bypass.
    • Achieved ​​ASHRAE A4 compliance​​ in 50kW/rack configurations.

​Case 2: Industrial IoT Edge Deployments​

  • Used in ​​Shell offshore platforms​​ for UCS C480 ML servers:
    • Blocked saltwater particulates from entering unoccupied PSU bays.
    • Eliminated 92% of dust-related maintenance interventions over 12 months.

​Integration Challenges and Field Solutions​

―――――――――――――――――――――――――――――――――――――――――――

  1. ​Misalignment in High-Vibration Environments​​:

    • ​Symptom​​: Plate rattling at 15Hz–200Hz in railway signaling cabinets.
    • ​Resolution​​: Installed ​​Cisco CAB-GASKET-5​​ vibration-damping pads.
  2. ​Galvanic Corrosion in Coastal Sites​​:

    • ​Trigger​​: Salt-induced oxidation reduced plate lifespan to 6 months.
    • ​Fix​​: Applied ​​Dow Corning 4​​ dielectric grease quarterly.
  3. ​Thermal Expansion Mismatch​​:

    • ​Issue​​: Warping at 65°C ambient in Middle Eastern DCs.
    • ​Mitigation​​: Replaced with ​​PWR-C5-BLANK-HV​​ (high-temp variant).

Source genuine PWR-C5-BLANK= plates for warranty compliance.


​Performance Benchmarks vs. Generic Blanks​

―――――――――――――――――――――――――――――――――――――――――――

  • ​Airflow Efficiency​​:
    98% slot sealing vs. 75% for third-party blanks – reduces bypass airflow by 23%.
  • ​Corrosion Resistance​​:
    2,000hr salt spray survival (ASTM B117) vs. 500hr for steel blanks.
  • ​EMI Shielding​​:
    15dB attenuation at 1GHz vs. 3dB for plastic blanks.
  • ​TCO​​:
    45vs.45 vs. 45vs.12 for generic plates – justified by 5-year warranty and 60% lower failure rate.

​Operational Best Practices​

―――――――――――――――――――――――――――――――――――――――――――

  1. ​Installation Protocol​​:

    • Use ​​CAB-TORQ-5​​ torque wrench (0.6–0.8Nm) for captive screws.
    • Verify flush mounting via ​​Cisco CHK-GAP-0.5​​ feeler gauge.
  2. ​Environmental Monitoring​​:

    • Track chassis intake temps with show environment temperature:
      PSU Bay 4:  
          Blanking Plate Installed: Yes  
          Adjacent Temp: 32°C  
    • Alert thresholds: >5°C differential between blanked/unblanked zones.
  3. ​Lifecycle Management​​:

    • Replace plates after ​​10 years​​ or visible corrosion.
    • Audit quarterly via ​​Cisco TAC-SI-4492​​ inspection checklist.

​Strategic Insights for Infrastructure Teams​

While often dismissed as a “dumb” component, the PWR-C5-BLANK= plays a ​​disproportionate role​​ in preventing cascade failures. A 2023 Meta study linked missing blanks to 12% of unplanned thermal shutdowns in their AI clusters. Yet, its ​​lack of telemetry integration​​ limits proactive monitoring – a gap Cisco could address with sensor-enabled blanks in future iterations. For enterprises balancing OpEx and resilience, this unassuming plate exemplifies how granular attention to infrastructure details drives macro-level reliability. The industry’s push toward liquid cooling may reduce reliance on airflow management, but until then, such components remain the unsung heroes of data center uptime.

Related Post

DS-C9396V-96EVK9P: How Does Cisco’s 96-Port

What Architectural Breakthroughs Power the DS-C9396V-96...

Cisco XR-NCS1K1-712K9= Network Convergence Sy

Modular Architecture & Hardware Innovations The Cis...

CBL-R1B-SD-240M6=: How Does It Optimize Cisco

Core Design and Technical Role The ​​CBL-R1B-SD-240...