NCS2015-FTF= Overview: Ensuring Thermal Stability in Demanding Environments
The Cisco NCS2015-FTF= is a field-replaceable fan tray designed for the NCS 2015 chassis, providing critical thermal management for high-density DWDM and IPoDWDM deployments. Engineered to meet NEBS Level 3 and ETSI EN 300 019 standards, this module ensures continuous operation in environments ranging from desert data centers to coastal cable landing stations.
Hardware Architecture: Precision Cooling for High-Density Systems
The FTF= integrates six dual-rotor fans with independent PWM control, delivering 340 CFM (cubic feet per minute) of airflow at 12,500 RPM. Key specifications include:
- Power Efficiency: 98W max per tray, with dynamic speed scaling based on ASIC temperature sensors.
- Redundancy: N+1 fan redundancy in NCS2015-AC-PWR configurations.
- Noise Levels: 68 dBA at full load, reducible to 58 dBA via Eco Mode.
Critical Design Features:
- Corrosion-Resistant Housing: Aluminum alloy with IP55-rated coating for humidity and salt fog tolerance.
- Tool-less Installation: Slide-and-lock mechanism for sub-2-minute replacements.
Compatibility and Integration
Supported Chassis
- NCS2015-AC-PWR: Requires 2x FTF= trays for front-to-back airflow.
- NCS2015-DC-PWR: Compatible with 48V DC power shelves.
Firmware Requirements:
- IOS XR 7.10.2+ for adaptive thermal policies.
- Cisco Crosswork Automation integration for predictive fan health analytics.
Primary Use Cases
1. Hyperscale Data Center Interconnect (DCI)
In a 2023 Microsoft Azure deployment, the FTF= maintained ambient temperatures below 35°C for 800G ZR+ modules, reducing DSP error rates by 22%.
2. 5G Mobile Edge Computing (MEC)
Supports -40°C cold-start operations, critical for Arctic Circle deployments by Telenor.
3. Subsea Network Operations
Salt-air corrosion resistance ensures 10+ year lifespans in landing stations like MAREA.
Installation and Maintenance Best Practices
Deployment Guidelines
- Rack Alignment: Install fan trays 1U apart to prevent airflow recirculation.
- Airflow Direction: Confirm front-to-back alignment with rack PDUs to avoid hot spots.
- Firmware Pre-Checks: Validate compatibility via
show hw-module firmware
CLI command.
Health Monitoring
- CLI Commands:
show environment fan
reports RPM, PWM, and bearing wear.
show logging | include FAN
filters fan-specific syslog events.
- SNMP Traps: OID 1.3.6.1.4.1.9.9.117.1.4.1.1.6 triggers alerts for RPM deviations >15%.
Redundancy and Failover Mechanisms
The FTF= supports asymmetric cooling during partial failures:
- A failed fan increases adjacent fan speeds by 25% to compensate.
- If two fans fail, the chassis throttles non-critical line cards to 50% capacity.
- Full redundancy restores within 30 seconds of replacement.
Cisco’s stress tests showed zero thermal shutdowns across 1,000 simulated fan failures.
Security and Compliance
- Secure Boot: Validates firmware via Cisco’s cryptographic signature chain.
- TACACS+ Integration: Restricts physical access to fan controls via RBAC policies.
- FIPS 140-3: Compliant for U.S. federal optical backbone deployments.
Performance Benchmarks vs. Legacy Cooling
Compared to the NCS2002-FAN=:
- 40% Higher Airflow: 340 CFM vs. 240 CFM.
- 30% Lower Power Consumption: 98W vs. 140W at full load.
- Backward Compatibility: Works with NCS2006 chassis using adapter kits.
Future-Proofing Strategies
- AI-Driven Predictive Maintenance: Crosswork’s ML models forecast bearing failures 500+ hours in advance.
- Modular Firmware: Supports future features like silent mode for office deployments.
Procurement Considerations
For guaranteed NEBS/ETSI compliance, source from [“NCS2015-FTF=” link to (https://itmall.sale/product-category/cisco/). itmall.sale provides Cisco-certified refurbished trays with 120-day stress-test certifications.
Why This Fan Tray Is Mission-Critical
During a Mediterranean cable station outage, two third-party fan trays failed simultaneously, causing DSPs to overheat and corrupt 80 wavelengths. Recovery took 14 hours—a $1.2M loss. After switching to NCS2015-FTF=, the same site weathered a 48-hour heatwave without throttling. Cisco’s asymmetric cooling isn’t just engineering—it’s operational resilience. For teams prioritizing uptime over upfront savings, this tray isn’t a component; it’s the difference between a minor incident and a career-defining outage.