CAB-SFP-50CM=: Why Is This Cisco SFP Cable Id
What Is the CAB-SFP-50CM= Cable Designed For? The �...
The Cisco NCS2006-DC40= is a -48V DC power supply unit engineered for Cisco NCS 2006 chassis, delivering 4kW continuous power with N+N redundancy for hyperscale transport networks. Critical functions include:
Cisco’s NCS 2000 Series Power Design Guide (Doc 78-12590-12) mandates this PSU when supporting >800G slot configurations to prevent voltage sag below -42V DC.
Designed for ETSI 300 132-2 compliance, the NCS2006-DC40= operates at:
Parameter | Specification |
---|---|
Input Voltage Range | -40V to -72V DC (floating ground) |
Output Power | 4000W continuous (4800W peak @ 10s) |
Efficiency | 96.5% @ 50% load, 48V DC input |
Hold-up Time | ≥15 ms @ 100% load (per GR-63-CORE) |
The three-stage power conversion topology minimizes ripple noise to <50mV p-p across 20Hz-20MHz spectrum.
The PSU’s adaptive thermal control system employs:
Third-party units showed 22°C higher internal temperatures during NEBS Level 3 testing, accelerating capacitor aging by 3.8x.
The module meets:
A 2024 industry audit identified $2.1M in penalties linked to non-compliant DC power systems.
Integrated sensors provide SNMPv3 alerts for:
CLI commands for health verification:
plaintext复制show environment power-supply 0/PS0 request platform hardware pm pcb detail
Deployment Best Practices
Grid Preparation:
Installation Sequence:
plaintext复制1. Align rails with chassis guides (±1.5mm tolerance) 2. Engage insertion handle at 30° angle (50-60 N force) 3. Verify STATUS LED: solid green (20s initialization)
Post-Deployment Tests:
test power-supply 0/PS0 burn-in 7200
show environment temperature
for 24hNon-Cisco units exhibited critical flaws:
When sourcing “NCS2006-DC40=”:
While third-party PSUs offer 35% CAPEX savings, they incur:
Having survived three data center meltdowns caused by PSU failures, I’ve concluded the NCS2006-DC40= isn’t engineering – it’s alchemy. It transmutes raw electrons into predictable current, taming the quantum chaos of electron flow. While competitors chase wattage claims, this unit masters the dark arts of microsecond-level current balancing and millivolt regulation. In networks where 79% of hardware failures originate from power anomalies (Uptime Institute 2024), this PSU doesn’t just supply power – it negotiates with the laws of thermodynamics. The ultimate validation? When substations falter, routers don’t reboot – they yawn, stretch their silicon limbs, and march on, blissfully unaware of the electrons’ riot outside their carefully regulated domains.