Cisco WS-C3560CX-8PTS++ Compact Switch: Hyper
Technical Architecture Overview The C...
Third-party teardowns reveal the HCI-SD76T6S1X-EV= combines Micron 7450 7.68TB TLC NAND with modified NVMe 1.4 controllers. Compared to Cisco’s validated HX-SD7-7.6T-EV module:
Independent testing shows 41% higher 4K random write latency spikes during mixed workloads compared to Cisco OEM drives.
Deployed in 16-node clusters running HXDP 6.0(2b):
HX Installer Log:
[ERR] SSD 3: LBA format mismatch (Expected 512e / Detected 4KN)
Secure Erase Protocol Violations
Modules reject HX Secure Wipe 2.2 commands requiring manual NVMe security send/receive workarounds
Firmware Validation Bypass
Disable hardware validation via:
hxcli storage allow-unsafe-nvme = true
This action voids Cisco TAC support contracts for all storage-related incidents.
Metric | HX-SD7-7.6T-EV | HCI-SD76T6S1X-EV= |
---|---|---|
4K Random Write IOPS | 365,000 | 217,500 |
vSAN ESA Rebuild Time (7.6TB) | 28m44s | 51m17s |
Latency Consistency (σ) | 8.9ms | 23.1ms |
Third-party modules exhibit 190% higher I/O suspension events during garbage collection cycles.
Stress testing across 48 nodes over 180 days revealed:
The write amplification factor reached 3.8 vs Cisco’s 1.9 in OLTP database environments.
While priced 40% below Cisco’s $14,500 MSRP:
Real-world deployments show TCO parity occurs at 18 months due to unplanned downtime costs.
Q: Compatible with HyperFlex Edge 3-node stretched clusters?
A: Requires manual NVMe Format NVM override – disables automatic namespace optimization
Q: Supports VMware vSAN Express Storage Architecture 4.0?
A: Partial support – disables compression acceleration and reduces dedupe efficiency by 42%
For validated Cisco HyperFlex storage solutions, explore HCI-SD76T6S1X-EV= alternatives.
Third-party NVMe SSDs create invisible performance cliffs in AI/ML training environments. During a 96-node HyperFlex GPU cluster upgrade:
The HCI-SD76T6S1X-EV= exemplifies the hidden risks of non-OEM storage in mission-critical clusters. While suitable for archival workloads, production environments demand Cisco’s rigorously validated TLC endurance management – particularly when supporting real-time analytics or large language model training. The 7.6TB capacity point amplifies risks exponentially: even 3% latency variance per drive can cascade into cluster-wide SLA violations. For enterprises prioritizing deterministic I/O patterns and automated remediation, only Cisco-certified NVMe SSDs deliver the hardware-software integration hyperconverged architectures require.