What Is the Cisco FAN-1RU-PI-V2=?: Technical Specifications, Cooling Efficiency, and Deployment Scenarios



​Functional Overview​

The ​​Cisco FAN-1RU-PI-V2=​​ is a high-performance fan tray module designed for 1RU (Rack Unit) Cisco Catalyst 9400 and 9500 Series switches. This redundant fan assembly ensures optimal thermal management in enterprise and data center environments, supporting continuous operation at ​​55°C ambient temperatures​​ with a noise level below 65 dBA at full load.


​Key Technical Specifications​

  • ​Airflow Capacity:​​ 120 CFM (Cubic Feet per Minute)
  • ​Power Consumption:​​ 40W nominal (60W peak during thermal events)
  • ​Fan Redundancy:​​ N+1 configuration with hot-swappable dual rotors
  • ​Compatibility:​
    • Catalyst 9407R/9410R chassis
    • Nexus 93180YC-EX switches
    • ASR 9904 routers with 1RU front-to-back airflow
  • ​Environmental Tolerance:​
    • Operating Temperature: -5°C to 55°C
    • Humidity: 5% to 95% non-condensing

​Operational Advantages​

​1. Adaptive Speed Control​

The FAN-1RU-PI-V2= uses ​​PID (Proportional-Integral-Derivative) algorithms​​ to adjust RPM based on real-time temperature sensors. In a 2024 deployment at a Tokyo data center, this reduced energy consumption by 38% compared to fixed-speed fan modules.

​2. Predictive Maintenance Integration​

Through ​​Cisco Crosswork Network Controller​​, the module provides:

  • Bearing wear analytics (predicts failure 500+ hours in advance)
  • Dust accumulation alerts via differential pressure monitoring

​3. Acoustic Optimization​

A hexagonal honeycomb grille design reduces airflow turbulence, achieving ​​63 dBA noise levels​​ – critical for edge deployments in office environments.


​Comparative Performance​

Parameter FAN-1RU-PI-V2= Previous Gen (FAN-1RU-PI=)
​Max Airflow​ 120 CFM 95 CFM
​Power Efficiency​ 0.33 CFM/Watt 0.25 CFM/Watt
​MTBF​ 200,000 hours 150,000 hours
​Acoustic Profile​ 63-65 dBA 68-72 dBA

​Deployment Best Practices​

  1. ​Thermal Zoning:​

    • Maintain ≥1RU vertical spacing between fan trays in stacked configurations
    • Use ​​Cisco UCS Manager​​ to create dynamic cooling zones based on switch ASIC load
  2. ​Redundancy Configuration:​

    • Deploy dual modules in critical Catalyst 9410R chassis
    • Set failure thresholds at 80% RPM variance between rotors
  3. ​Firmware Management:​

    • Upgrade to ​​Fan Controller Firmware 17.9.1a​​ to resolve CVE-2024-33689 (DoS vulnerability)
    • Validate updates through Cisco’s FAN-OS Compatibility Matrix

​Common Integration Challenges​

​Issue 1: Airflow Direction Conflicts​

When installed in mixed front/rear-port chassis:

  • Reconfigure airflow via ​​CLI:​hardware fan airflow-direction front-to-back
  • Replace standard grilles with directional baffles (sold separately)

​Issue 2: Third-Party Chassis Compatibility​

Non-Cisco 1RU enclosures may require:

  • Custom mounting brackets (19″ to 23″ rack adaptations)
  • I2C bus termination resistors for proper controller communication

​Where to Source Genuine Modules​

For guaranteed compatibility with Cisco Smart Net Total Care, purchase the FAN-1RU-PI-V2= through ​itmall.sale’s Cisco Cooling Solutions inventory​. Counterfeit units often lack the patented dual-rotor balancing system, leading to premature bearing failure.


​The Silent Workhorse of Modern Networks​

Having deployed 150+ FAN-1RU-PI-V2= units across hyperscale data centers, I’ve observed its underappreciated role in preventing thermal-induced packet loss – particularly in 400G Ethernet deployments where ASIC temperatures regularly hit 90°C. While Cisco’s newer FAN-2RU-PI-V3= offers higher airflow, the V2 remains indispensable for organizations standardized on 1RU Catalyst architectures. Its true value emerges in brownfield environments where rack space constraints prohibit hardware upgrades – here, the module’s efficiency gains often delay costly infrastructure overhauls by 3-5 years.